Removing and replacing Fiery X3e components
T
O
 
REPLACE
 
THE
 HDD
C
AUTION
:
Wear an ESD grounding wrist strap and follow standard ESD (electrostatic 
discharge) precautions before handling Fiery X3e components. 
1.
Handle the HDD with care. 
Do not touch it with magnetic objects or place any objects near it that are sensitive to 
magnets. See “Proper handling” on page 17.
2.
Insert the HDD cable into the HDD. 
Make sure the other end of the cable is securely attached to the motherboard PRIMARY 
IDE DRIVE connector. 
3.
Secure the HDD to the pan using the four screws you removed earlier (see Figure L on 
page 18).
4.
Reassemble the unit and verify functionality (see page 20).
Connect the power cable to the HDD. 