4-6
4
Troubleshooting Procedures
Run Diagnostics function
One of the menu items in the Functions screen on the Fiery AR-PE2 Operation Panel is 
Run Diagnostics. Select Run Diagnostics if you want to run Video Diagnostics. 
Video Interface Diagnostics
If you suspect there may be a problem with the video interface on the Fiery AR-PE2 
board (for example, the print quality of output is poor), you can run Test I/F Board. 
Video Diagnostics loops data internally, comparing data sent with data received to make 
sure no errors have occurred.
T
O
 
RUN
 V
IDEO
 D
IAGNOSTICS
1.
Power on the copier. Once the Fiery AR-PE2 has reached the Info screen, press the Menu 
button to view the Functions menu.
2.
Select Run Diagnostics, then Test I/F Board.
3.
If “Board diagnostics passed” appears, press the Menu (or OK) button to return to the 
Functions menu.
4.
If “Board diagnostics failed” appears, you may have to replace the Fiery AR-PE2 board.
Page of 62