Read Sharp AR-PE2 (serv.man6) Service Manual online
4-6
4
Troubleshooting Procedures
Run Diagnostics function
One of the menu items in the Functions screen on the Fiery AR-PE2 Operation Panel is
Run Diagnostics. Select Run Diagnostics if you want to run Video Diagnostics.
Run Diagnostics. Select Run Diagnostics if you want to run Video Diagnostics.
Video Interface Diagnostics
If you suspect there may be a problem with the video interface on the Fiery AR-PE2
board (for example, the print quality of output is poor), you can run Test I/F Board.
Video Diagnostics loops data internally, comparing data sent with data received to make
sure no errors have occurred.
board (for example, the print quality of output is poor), you can run Test I/F Board.
Video Diagnostics loops data internally, comparing data sent with data received to make
sure no errors have occurred.
T
O
RUN
V
IDEO
D
IAGNOSTICS
1.
Power on the copier. Once the Fiery AR-PE2 has reached the Info screen, press the Menu
button to view the Functions menu.
button to view the Functions menu.
2.
Select Run Diagnostics, then Test I/F Board.
3.
If “Board diagnostics passed” appears, press the Menu (or OK) button to return to the
Functions menu.
Functions menu.
4.
If “Board diagnostics failed” appears, you may have to replace the Fiery AR-PE2 board.
Click on the first or last page to see other AR-PE2 (serv.man6) service manuals if exist.