Read Sharp AR-P16 (serv.man8) User Guide / Operation Manual online
8
Easy Calibration (additional information for Step 6 on the previous page)
Easy Calibration is performed by selecting the desired colour of grey (processed grey), which is a combi-
nation of cyan, magenta, and yellow.
nation of cyan, magenta, and yellow.
Test patterns 2 and 3 indicate processed grey colours with the current grey colour as the reference
point or origin (
point or origin (
“
0”).
• The X axis shows the density of magenta in seven increments from -3 to +3 (-3 to 0 in test pattern 2 and
0 to +3 in test pattern 3).
• The Y axis shows the density of yellow in seven increments from -3 to +3.
• The density of cyan is constant.
• The density of cyan is constant.
1
Select the processed grey colour that you prefer from test pattern 2 or test pattern 3.
For example, if you prefer the colour indicated above in test pattern 3, select “+1” for X and “+2” for Y.
For example, if you prefer the colour indicated above in test pattern 3, select “+1” for X and “+2” for Y.
2
Enter the X and Y coordinates of the colour you prefer in the following screen (the screen in Step 6
on the previous page).
on the previous page).
How to use the keys in the screen
:Touch the
,
,
and
keys to select the desired colour of grey.
3
Back to step 7 on the previous page.
Test Pattern 2 (printed by printer)
Test Pattern 3 (printed by printer)
Magenta
(-3~
(-3~
±
0)
Magenta
(
(
±
0~-3)
Example:if this is
the desired
colour, select
“+1” for X and
“+2” for Y.
the desired
colour, select
“+1” for X and
“+2” for Y.
Yellow
(-3~+3)
(-3~+3)
Yellow
(-3~+3)
(-3~+3)
SHARP CORPORATION
PRINTED IN CHINA