AR-M700 (serv.man28). Self diag message and troubleshooting - Sharp Copying Equipment Service Manual (repair manual). Page 34

Read Sharp AR-M700 (serv.man28) Service Manual online

AR-M550/M620/M700  SELF DIAG MESSAGE AND TROUBLESHOOTING  9 - 34
Main 
code
Sub 
code
Title
Counter check sum error (MFP 
control)
U2
11
Phenomenon
Display
Lamp
Message
Details
Counter data area check 
sum error
Section
Controller
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
EEPROM trouble
Remedy
Check that the EEPROM 
is properly installed.
In the simulation to 
prevent against delete of 
the counter data/
adjustment values, write 
down the counter/
adjustment values.
Note 
Case 2
Trouble 
position/
Cause
Control circuit runaway 
due to noises
Remedy
Use SIM 16 to cancel the 
U2 trouble.
Note 
Case 3
Trouble 
position/
Cause
MFP control PWB 
EEPROM access circuit 
trouble
Remedy
Replace the MFP control 
PWB.
Note 
Main 
code
Sub 
code
Title
Adjustment value check sum error 
(MFP control)
U2
12
Phenomenon
Display
Lamp
Message
Details
Adjustment value data 
area check sum error
Section
Controller
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
EEPROM trouble
Remedy
Check that the EEPROM 
is properly installed.
In the simulation to 
prevent against delete of 
the counter data/
adjustment values, write 
down the counter/
adjustment values.
Note 
Case 2
Trouble 
position/
Cause
Control circuit runaway 
due to noises
Remedy
Use SIM 16 to cancel the 
U2 trouble.
Note 
Case 3
Trouble 
position/
Cause
MFP control PWB 
EEPROM access circuit 
trouble
Remedy
Replace the MFP control 
PWB.
Note 
Main 
code
Sub 
code
Title
SRAM memory check sum error 
(MFP control)
U2
22
Phenomenon
Display
Lamp
Message
Details
MFPC section SRAM 
memory check sum error
SRAM check sum error 
when turning on the 
power.
(If this error occurs, 
initialize the one-touch 
dial and the FAX soft 
switches.)
Section
Controller
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
SRAM trouble
Remedy
Initialize the 
communication 
management table 
registered in the SRAM 
and the FAX soft switch.
Since the registered data 
are deleted, register the 
data again.
Note 
Case 2
Trouble 
position/
Cause
Control circuit runaway 
due to noises
Remedy
Use SIM 16 to cancel the 
U2 trouble.
Note 
Case 3
Trouble 
position/
Cause
MFP control PWB 
EEPROM access circuit 
trouble
Remedy
Replace the MFP control 
PWB.