EEPROM red/write error (Scanner)
U2
80
Phenomenon
Display
Lamp
Message
Details
EEPROM red/write error 
(Scanner)
EEPROM communication 
trouble (NACK detection) 
Retry 3 times
Section
Scanner
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
EEPROM trouble
Remedy
Check that the EEPROM 
is properly installed.
In the simulation to 
prevent against delete of 
the counter data/
adjustment values, write 
down the counter/
adjustment values.
Note 
Case 2
Trouble 
position/
Cause
Insertion of EEPROM 
which is not initialized
Remedy
Use SIM 16 to cancel the 
U2 trouble.
Note 
Case 3
Trouble 
position/
Cause
Scanner PWB EEPROM 
access circuit trouble
Remedy
Replace the scanner 
PWB.
Note 
Main 
code
Sub 
code
Title
Memory check sum error (Scanner)
U2
81
Phenomenon
Display
Lamp
Message
Details
Memory check sum error 
(Scanner)
When counter data sum 
error is detected.
Section
Scanner
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
EEPROM trouble
Remedy
Check that the EEPROM 
is properly installed.
In the simulation to 
prevent against delete of 
the counter data/
adjustment values, write 
down the counter/
adjustment values.
Note 
U2
81
Case 2
Trouble 
position/
Cause
Control circuit runaway 
due to noises
Remedy
Use SIM 16 to cancel the 
U2 trouble.
Note 
Case 3
Trouble 
position/
Cause
Scanner PWB EEPROM 
access circuit trouble
Remedy
Replace the scanner 
PWB.
Note 
Main 
code
Sub 
code
Title
EEPROM read/write error (PCU)
U2
90
Phenomenon
Display
Lamp
Message
Details
EEPROM read/write error 
(PCU)
EEPROM communication 
trouble (NACK detection) 
Retry 3 times
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
EEPROM trouble
Remedy
Check that the EEPROM 
is properly installed.
In the simulation to 
prevent against delete of 
the counter data/
adjustment values, write 
down the counter/
adjustment values.
Note 
Case 2
Trouble 
position/
Cause
Insertion of EEPROM 
which is not initialized
Remedy
Use SIM 16 to cancel the 
U2 trouble.
Note 
Case 3
Trouble 
position/
Cause
PCU PWB EEPROM 
access circuit trouble
Remedy
Replace the PCU PWB.