AR-M700 (serv.man28). Self diag message and troubleshooting - Sharp Copying Equipment Service Manual (repair manual). Page 30

Read Sharp AR-M700 (serv.man28) Service Manual online

AR-M550/M620/M700  SELF DIAG MESSAGE AND TROUBLESHOOTING  9 - 30
Main 
code
Sub 
code
Title
5-time continuous POD not-
reached JAM detection
H5
01
Phenomenon
Display
Lamp
Message
Details
5-time continuous POD 
not-reached JAM 
detection
When POD1 not-reached 
jam is detected 5 times 
continuously.
POD1 jam counter is 
backed up and used in a 
print job after turning on 
the power.
The counter is cleared 
when POD1 jam does not 
occur in a job or when the 
trouble is canceled.
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
The fusing jam is not 
canceled completely. 
(Jam paper remains.)
Remedy
Check for jam paper in 
the fusing section. 
(Winding, etc.)
Case 2
Trouble 
position/
Cause
POD1 sensor trouble, or 
harness connection 
trouble
Remedy
Check the PODC1 
sensor harness and 
installation of the fusing 
unit.
Case 3
Trouble 
position/
Cause
Fusing unit installation 
trouble
Remedy
Use SIM 14 to cancel the 
trouble
Main 
code
Sub 
code
Title
Scanner feed trouble
L1
00
Phenomenon
Display
Lamp
Message
Details
Scanner feed trouble
Scanner feed is not 
completed within the 
specified time.
When MHP Soft is not 
detected within 2 sec 
after shifting the mirror 
base unit in the feeding 
direction.
Section
Scanner
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Scanner unit trouble
The scanner wire is 
disconnected.
Remedy
Use SIM 1-1 to check 
scanning operation.
Note 
Main 
code
Sub 
code
Title
Scanner return trouble
L3
00
Phenomenon
Display
Lamp
Message
Details
Scanner return trouble
Scanner return is not 
completed within the 
specified time.
MHPSon is not detected 
within 10sec after starting 
the mirror base unit in the 
return direction.
Section
Scanner
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Scanner unit trouble
The scanner wire is 
disconnected.
Remedy
Use SIM 1-1 to check 
scanning operation.
Note 
Main 
code
Sub 
code
Title
Main motor lock detection
L4
01
Phenomenon
Display
Lamp
Message
Details
Main motor lock detection
Three successive trouble 
signals are detected after 
600 msec from starting 
the main motor.
No trouble is detected 
after 600msec above.
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Main motor trouble
Remedy
Use SIM 6-1 to check the 
main motor operation.
Note 
Case 2
Trouble 
position/
Cause
Improper disconnection 
of the harness between 
the PCU PWB and the 
main motor
Control circuit trouble
Remedy
Check the harness and 
the connector between 
the PCU PWB and the 
main motor.
Note 
Page of 38
Display