Read Sharp AR-EF1 (serv.man15) Technical Bulletin online
Sharp Electronics (UK) Ltd., Technical Services Group
ARE757
1. Model Name
AREF1
2. Symptom
There have been cases where an SPOD_N jam is caused by a failure by the non
exiting the unit completely.
3.Description
To reduce the jams (SPOD_N or SPOD_S) a change has been made to the sponge and
the delivery jam sensor to parts which have been used in other models. At the same time
the delivery sheet has been discontinued.
4. Action
From April 2005 production.
Reduction in SPF delivery jam (SPOD_N or SPD_S)
TECHNICAL BULLETIN
Date:
27
th
June 2005
Model:
AREF1
Ref.:
023
Colour:
White
Page:
1 of 2
Sharp Electronics (UK) Ltd., Technical Services Group
ARE757
5. Part Action
Current parts
New parts
Ref.
No.
Model
name
Version P/G No.
Parts code
Parts code
Price
rank
Parts name
Effectiv
e
time
Inter-
change-
ability
Number
1-19
PSPO-0002FCZZ
PCUSS0383FCZZ
AN
Sponge
4
8-63
QSW-Z0536FCZZ
QSW-Z0544FCZZ
AY
Delivery jam
sensor
sensor
1
1
AR-EF1
ALL
8-78
PSHEZ4957FCZZ
---
---
Delivery sheet
2005/4
5
---
<Interchange>
1. Interchangeable.
4. Not interchangeable.
2. Current type can be used in place of new
type.
type.
New type cannot be used in place of current
type.
type.
5. Interchangeable if replaced with same types of
related parts in use.
3. Current type cannot be used in place of new
type.
type.
New type can be used in place of current
type.
type.
6. Others.
Parts marked with "
" is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
Display