AR-M700 (serv.man28). Self diag message and troubleshooting - Sharp Copying Equipment Service Manual (repair manual). Page 31

Read Sharp AR-M700 (serv.man28) Service Manual online

AR-M550/M620/M700  SELF DIAG MESSAGE AND TROUBLESHOOTING  9 - 31
Main 
code
Sub 
code
Title
Drum motor lock detection
L4
02
Phenomenon
Display
Lamp
Message
Details
Drum motor lock 
detection
The motor lock signal is 
detected for 1.5sec 
during rotation of the 
drum motor.
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Drum motor trouble
Remedy
Use SIM 6-1 to check the 
drum motor operation.
Note 
Case 2
Trouble 
position/
Cause
Improper connection of 
the harness between the 
PCU PWB and the drum 
motor
Control circuit trouble
Remedy
Check the harness and 
the connector of the PCU 
PWB, and the drum 
motor.
Note 
Main 
code
Sub 
code
Title
Fusing motor lock detection
L4
03
Phenomenon
Display
Lamp
Message
Details
Fusing motor lock 
detection
Three successive trouble 
signals are detected after 
600 msec from starting 
the fusing motor.
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Fusing motor trouble
Remedy
Use SIM 6-1 to check the 
fusing motor operation.
Note 
Case 2
Trouble 
position/
Cause
Improper connection of 
the harness between the 
PCU PWB and the fusing 
motor
Control circuit trouble
Remedy
Check connection of the 
harness and the 
connector between the 
PCU PWB and the fusing 
motor.
Note 
Main 
code
Sub 
code
Title
Developing motor lock detection
L4
04
Phenomenon
Display
Lamp
Message
Details
Developing motor lock 
detection
The motor lock signal is 
detected for 1.5sec 
during rotation of the 
developing motor
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Developing motor trouble
Remedy
Use SIM 6-1 to check the 
developing motor 
operation.
Note 
Case 2
Trouble 
position/
Cause
Improper connection of 
the harness between the 
PCU PWB and the 
developing motor
Control circuit trouble
Remedy
Check the harness and 
the connector between 
the PCU PWB and the 
developing motor.
Note 
Main 
code
Sub 
code
Title
Transfer belt separation motor 
trouble detection
L4
06
Phenomenon
Display
Lamp
Message
Details
Transfer belt separation 
motor trouble detection
The transfer belt home 
position sensor ON/OFF 
is not detected within the 
specified time (4 sec) 
during operation of the 
transfer belt (separation, 
contact).
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Transfer belt separation 
motor trouble
Remedy
Use SIM 6-1 to check the 
transfer belt motor 
operation.
Note 
Case 2
Trouble 
position/
Cause
Improper connection of 
the harness between the 
PCU PWB and the 
transfer belt separation 
motor.
Control circuit trouble
Remedy
Check connection of the 
harness and the 
connector between the 
PCU PWB and the fusing 
motor.
Note 
Page of 38