Read Sharp AR-M550 (serv.man15) Service Manual online
AR-M550/M620 SIMULATION 8 - 80
Operation/Procedure
1) Select YES/NO of hard disk read/write check.
2) Press [START] key.
During testing, "EXECUTING" is displayed. When test is completed
normally, "OK" is displayed. If not, "NG" is displayed.
normally, "OK" is displayed. If not, "NG" is displayed.
Operation/Procedure
1) Select the number corresponding to the self diag check mode.
2) Press [START] key.
During the self diag operation, "EXECUTING" is displayed.
If the self diag is completed normally, "0" is displayed. If not, any value
but 0 is displayed.
but 0 is displayed.
* = SHORT SELF-TEST, EXTENDED SELF-TEST
Operation/Procedure
1) Enter 1 with 10-key.
2) Press [START] key.
The result of the hard disk operation check (the self diag operation of
the SMART function) is printed out.
the SMART function) is printed out.
Completion
Press [CUSTOM SETTINGS] key.
62-3
Purpose
Operation test/Check
Function
(Purpose)
(Purpose)
Used to check the operation of the hard disk (read/
write). (All areas check)
write). (All areas check)
Section
MFP controller (HDD)
Item
Operation
1
YES
Execution
2
NO
Cancel
Completion
Press [CUSTOM SETTINGS] key.
62-6
Purpose
Operation test/Check
Function
(Purpose)
(Purpose)
Used to check the operations of the hard disk. (The
self diag operation of the SMART function is
executed.)
self diag operation of the SMART function is
executed.)
Section
MFP controller (HDD)
Item
Clear
1
SHORT SELF-TEST
Partial test
2
EXTENDED SELF-TEST
All areas test
SIMULATION 62-2
HDD R/W TEST.
ARE YOU SURE?
1. YES
2. NO
1
Press [START] key.
SIMULATION 62-2
HDD R/W TEST. EXECUTING···.
SIMULATION 62-2
HDD R/W TEST. OK. (or NG)
SIMULATION 62-3
HDD R/W TEST(ALL).
ARE YOU SURE?
1. YES
2. NO
1
Press [START] key.
SIMULATION 62-3
HDD R/W TEST(ALL). EXECUTING···.
SIMULATION 62-3
HDD R/W TEST(ALL). OK. (or NG)
Completion
Press [CUSTOM SETTINGS] key.
62-7
Purpose
Operation test/Check
Function
(Purpose)
(Purpose)
Used to check the operations of the hard disk. (The
result of the self diag operation of the SMART function
is printed out.)
result of the self diag operation of the SMART function
is printed out.)
Section
MFP controller (HDD)
Item
Clear
0
TRAY SELECT
Tray select auto only (Selection inhibited)
1
PRINT START
Print start
Select 1 and
press [START] key.
press [START] key.
Press [CUSTOM SETTINGS] key
or [START] key.
or [START] key.
62-8
Purpose
Data clear
Function
(Purpose)
(Purpose)
Used to format the hard disk (the system area
excluded).
excluded).
Section
MFP controller (HDD)
Item
Clear
SIMULATION 62-6
SMART OFFLINE TEST.
1. SHORT SELF-TEST
2. EXTENDED SELF-TEST
1
SIMULATION 62-6
*. EXECUTING···.
Press [START] key.
SIMULATION 62-6
*. COMPLETE.. (result: 0)
SIMULATION 62-7
SMART ERROR LOG PRINT OUT. SELECT SETTING, AND PRESS
START.
0. TRAY SELECT :AUTO ONLY
1. PRINT START
1
0
SIMULATION 62-7
SMART ERROR LOG PRINT OUT. EXECUTING···
0. TRAY SELECT :
1