AR-LC5 (serv.man3). AR-LC5 Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 3

Read Sharp AR-LC5 (serv.man3) Service Manual online

AR-LC5  UNPACKING AND INSTALLATION  3 - 2
2) Attach the mounting plates A and B.
<1> Attach the two upper mounting plates with the rubber portion
(
) down to the right side of the main unit using screws B
(two for each). (See the illustration below.)
<2> Attach the mounting plate to the lower right side of the
optional stand using two screws A.
<3> Remove the two screws that secure the LCC cover on the
right side of the main unit and then remove the LCC cover.
3)  Attach the connecting plate to the large capacity tray.
<1> Remove the two bottom plate securing stepped screws
attached to the large capacity tray.
<2> Insert the connecting plate with the marking surface up into
the lower part of the large capacity tray from the marking
side.
<3> Attach the connecting plate by inserting screw C into the hole
of marking "A" of the connecting plate.
4) Attach the large capacity tray to the main unit.
<1> Insert the connecting plate attached to the large capacity tray
to the mounting plate at the lower part of the optional stand
until the base is inserted.
At this time, lift the leading end of the connecting plate a little
to insert the plate easily.
<2> Gently detach the large capacity tray from the main unit and
check that the tray is locked.
<3> With the tray locked, attach the securing plate with two
screws D.
5) Adjust the height of the large capacity tray.
<1> Move the large capacity tray near the main unit.
<2> Adjust the height using the following procedure so that the rib
of the large capacity tray is aligned with the axis of mounting
plate A attached to the main unit viewing from the top.
• If the axis is aligned with the rib:
Push the large capacity tray into the main unit.
• If the rib is displaced to the right of the axis:
<1> Loosen the two screws of the adjusting caster mounting plate
attached to the lower part of the large capacity tray.
<2> Turn the knob clockwise viewing from the top so that the rib is
aligned with the axis.
<3> After adjustment is complete, tighten the two screws of the adjust-
ing caster mounting plate and push the large capacity tray into the
main unit.
• If the rib is displaced to the left of the axis:
<1> Loosen the two screws of the adjusting caster mounting plate
attached to the lower part of the large capacity tray.
<2> Turn the knob counterclockwise viewing from the top so that the
rib is aligned with the axis.
<3> After adjustment is complete, tighten the two screws of the adjust-
ing caster mounting plate and push the large capacity tray into the
main unit.
Screws B
 Screws A
Screws
LCC cover
Upper
mounting
plate
Upper
mounting
plate
Mounting
plate
<Note>
Upper
mounting
plate
Rubber
portion
Screw C
Connecting plate
Stepped
screws
Connecting plate
Mounting plate
Securing plate
Screws D
Axis
Rib
Top view
Rib
Axis
Screw
Top view
Knob
Rib
Axis
Screw
Top view
Knob
Page of 28