Fusing motor trouble
L4
3
Phenomena Display
Lamp
Message
Message
Detail
The motor lock signal is detected for 50ms or more during rotation of the fusing motor.
Section
Paper feed
Operation mode
Paper feed
Note
Case 1
Trouble
position/cause
position/cause
Fusing motor trouble
Remedy
(Check) Check the fusing motor operation. (SIM 6-1)
(Repair) Replace the fusing motor. / Power Source-ON
(After-work)
(Repair) Replace the fusing motor. / Power Source-ON
(After-work)
Note
Case 2
Trouble
position/cause
position/cause
PCU MAIN PWB trouble
Remedy
(Check)
(Repair) Replace the PCU MAIN PWB. / Power Source-ON
(After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU
MAIN PWB to a new PCU MAIN PWB.)
(Repair) Replace the PCU MAIN PWB. / Power Source-ON
(After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU
MAIN PWB to a new PCU MAIN PWB.)
Note
Case 3
Trouble
position/cause
position/cause
Fusing mechanism section trouble.
Remedy
(Check) Check the loads in the fusing mechanism section.
(Repair) Repair or replace parts in the fusing mechanism section. / Power Source-ON
(After-work)
(Repair) Repair or replace parts in the fusing mechanism section. / Power Source-ON
(After-work)
Note
Main
code
Sub
code
Title
Developing motor trouble (BLACK)
L4
4
Phenomena Display
Lamp
Message
Message
Detail
The motor lock signal is detected for 3.5sec or more when the developing motor is ON.
Section
Developing drive
Operation mode
Warm-up / Copy / Print
Note
Case 1
Trouble
position/cause
position/cause
Developing motor trouble
Remedy
(Check) Check the developing motor operation (SIM 25-1).
(Repair) Replace the developing motor. / Power Source-ON
(After-work)
(Repair) Replace the developing motor. / Power Source-ON
(After-work)
Note
Case 2
Trouble
position/cause
position/cause
Developing mechanism section trouble
Remedy
(Check) Check the loads of the developing mechanism section.
(Repair) Repair or replace the parts in the developing mechanism section. / Power Source-ON
(After-work)
(Repair) Repair or replace the parts in the developing mechanism section. / Power Source-ON
(After-work)
Note
Case 3
Trouble
position/cause
position/cause
PCU MAIN PWB trouble
Remedy
(Check)
(Repair) Replace the PCU MAIN PWB. / Power Source-ON
(After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU
MAIN PWB to a new PCU MAIN PWB.)
(Repair) Replace the PCU MAIN PWB. / Power Source-ON
(After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU
MAIN PWB to a new PCU MAIN PWB.)
Note
10 – 8A