AR-C270 (serv.man14). (Section 10) Self Diag Message Troubleshooting - Sharp Copying Equipment Service Manual (repair manual). Page 4

Read Sharp AR-C270 (serv.man14) Service Manual online

Main 
code
Sub
code
Title (Content)
Section 
Operation mode
Remedy
NOTE
F2
58
Process humidity sensor trouble
Image process
(Transfer)
All modes
Power
source-ON
In the case of AR-C100, the error code
is displayed (print disabled). In the
case of AR-C150/C250/C160/C270,
the error code is stored in the trouble
memory (print enabled).
F2
63
Temperature sensor trouble (Image
process)
Image process
All modes
Power
source-ON
In the case of AR-C100, the error code
is displayed (print disabled). In the
case of AR-C150/C250/C160/C270,
the error code is stored in the trouble
memory (print enabled).
F2
80
Half tone correction (1st patch) trouble
(BLACK)
Image process 
Image density
correction 
Power
source-ON
F2
81
Half tone correction (1st patch) trouble
(CYAN)
Image process 
Image density
correction 
Power
source-ON
F2
82
Half tone correction (1st patch) trouble
(MAGENTA)
Image process 
Image density
correction 
Power
source-ON
F2
83
Half tone correction (1st patch) trouble
(YELLOW)
Image process 
Image density
correction 
Power
source-ON
F2
84
Half tone correction (2nd patch)
trouble (BLACK)
Image process 
Image density
correction 
Power
source-ON
F2
85
Half tone correction (2nd) patch
trouble (CYAN)
Image process 
Image density
correction 
Power
source-ON
F2
86
Half tone correction (2nd) patch
trouble (MAGENTA)
Image process 
Image density
correction 
Power
source-ON
F2
87
Half tone correction (2nd) patch
trouble (YELLOW)
Image process 
Image density
correction 
Power
source-ON
F2
90
Half tone correction trouble
Image process 
Image density
correction 
Power
source-ON
F3
12
Lift-up trouble (Paper 1)
Paper tray 1
Paper tray lift up
Power
source-ON
F3
22
Lift-up trouble (Paper 2)
Paper tray 2
Paper tray lift up
Power
source-ON
F3
32
Lift-up trouble (Paper 3)
Paper tray 3
Paper tray lift up
Power
source-ON
F3
42
Lift-up trouble (Paper 4)
Paper tray 4
Paper tray lift up
Power
source-ON
F9
0
ICU PWB-printer controller
communication trouble (ICU detection)
ICU IMAGE PWB /
PRINTER
CONTROLLER
Warm-up / Printing Power
source-ON
H2
0
Fusing main temperature sensor
(lower)(Thermistor) open/Fusing unit
not-installed (THS1)
Fusing
All modes
Power
Source-ON
H2
1
Fusing main temperature sensor
(lower)(Thermistor) open/Fusing unit
not-installed (THS2)
Fusing
All modes
Power
Source-ON
H2
2
Fusing main temperature sensor
(upper)(Thermistor) open/Fusing unit
not-installed (THS3)
Fusing
All modes
Power
Source-ON
H2
3
Fusing main temperature sensor
(upper)(Thermistor) open/Fusing unit
not-installed (THS4)
Fusing
All modes
Power
Source-ON
H3
0
Fusing section high temperature
trouble (THS1)
Fusing
All modes
SIM 14
H3
1
Fusing section high temperature
trouble (THS2)
Fusing
All modes
SIM 14
H3
2
Fusing section high temperature
trouble (THS3)
Fusing
All modes
SIM 14
H3
3
Fusing section high temperature
trouble (THS4)
Fusing
All modes
SIM 14
H4
0
Fusing section (upper) low
temperature trouble (HL1)
Fusing
All modes
SIM 14
H4
1
Fusing section (lower) low temperature
trouble (HL2)
Fusing
All modes
SIM 14
H5
1
Paper jam in the fusing/paper exit
sections
Fusing
Copy / Print
SIM 14
10 –  4A
Page of 10
Display

Click on the first or last page to see other AR-C270 (serv.man14) service manuals if exist.