AR-C270 (serv.man14). (Section 10) Self Diag Message Troubleshooting - Sharp Copying Equipment Service Manual (repair manual). Page 6

Read Sharp AR-C270 (serv.man14) Service Manual online

Main 
code
Sub
code
Title (Content)
Section 
Operation mode
Remedy
NOTE
U5
3
RADF timing sensor trouble
RADF
RADF
Power
Source-ON
U5
11
RADF paper feed motor trouble
RADF
RADF
Power
Source-ON
U6
9
Large capacity tray (LCC) lift motor
trouble
Large capacity tray
Paper feed
SIM 15
U6
20
PCU MAIN PWB-Large capacity tray
(LCC) communication trouble
Large capacity tray
control PWB / PCU
MAIN PWB
Warm-up /
Initialize
Power
Source-ON
U6
21
Large capacity tray (LCC) transport
motor trouble
Large capacity tray
Paper feed
Power
Source-ON
U6
22
Large capacity tray (LCC) 24v power
trouble
Large capacity tray  All modes
Power
Source-ON
U7
0
RIC communication trouble
PCU PWB
RIC
communication 
Power
Source-ON
UC
0
ICU SCAN PWB - CPT PWB
communication trouble
ICU SCAN PWB /
CPT PWB
Copy
Power
Source-ON
UC
1
CPT board program trouble
CPT PWB
Warm-up /
Initialize
Power
Source-ON
UC
2
CPT board ASIC trouble
CPT PWB
Warm-up /
Initialize
Power
Source-ON
UC
3
CPT board ROM trouble
CPT PWB
Warm-up /
Initialize
Power
Source-ON
UC
4
CPT board RAM trouble
CPT PWB
Warm-up /
Initialize
Power
Source-ON
UC
5
CPT board model code data trouble
ICU MAIN PWB /
CPT PWB
Warm-up /
Initialize
Power
Source-ON
6. Details
Main 
code
Sub
code
Title
Shading trouble (White correction)
E7 11
Phenomena Display
Lamp
Message
Detail
In shading correction, the CCD white reading level is abnormal (with the scanner lamp OFF).
Section
Scanner (reading) / ICU SCAN PWB
Operation mode
Warm-up / Initialize
Note
Case 1
Trouble
position/Cause
Improper CCD white level gain
Too great CCD white level gain
Remedy
(Check)
  1) Use SIM 63-1 to check the values of ADJUST ODD GAIN and ADJUST EVEN GAIN of each color
      of R/G/B. (There are six values in total.) (AR-C150)
  2) Add 25 to each value of GAIN ODD and GAIN EVEN of R/G/B checked in procedure 1) and make
      notes of the total values. (AR-C150)
  3) Enter the SIM 46-6 mode, and replace each value of GAIN ODD and GAIN EVEN of R/G/B with 
      the total values calculated in procedure 2). (Input the new value.) (AR-C150)
  4) Cancel the simulation.
  5) Turn OFF/ON the power, and shading operation will be performed. 
(Repair) Power OFF-ON
(After work)
Note
This trouble occasionally happens when the CCD unit (with the lens) is replaced. 
Case 2
Trouble
position/cause
Bad connection of the flat cable between the CCD unit and the ICU SCAN PWB. 
Remedy
(Check) Check connection of the flat cable between the CCD unit and the ICU SCAN PWB.
(Repair) Replace the flat cable between the CCD unit and the ICU SCAN PWB. / Power Source-ON
(After-work)
Note
10 –  6A
Page of 10
Display