AR-C260 (serv.man12). (9) Test Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 40

Read Sharp AR-C260 (serv.man12) Service Manual online

AR-C260/C260M  SIMULATION  9 - 40
(Display items)
(Set items)
If the adjustment is not completed normally, "ERROR" is displayed.
In case of an error, the contents of the adjustment are not revised.
(Display items)
D (DRAWING 
MODE (LOW)
Actual main charger grid voltage /Developing 
bias voltage (drawing, low speed mode) 
(YMCK)
TEMP AREA
Temperature area
TEMP
Temperature (HEX value)
HUMIDITY AREA
Humidity
HUMIDITY
Humidity (HEX value)
MD X STEP 
(M/L/H)
Photoconductor drum membrane decrease 
correction step (Max. 4 steps) /Correction 
voltage
CONVERSION
Discrimination of Sharp version and other 
company version of toner cartridge (0: 
SHARP, 1: Other company)
DESTINATION
Destination of toner cartridge stored in the 
machine memory
MODEL TYPE
Toner cartridge application model (DM/AR)
CRUM 
DESTINATION (X)
Toner cartridge destination
DV X STEP (X)
Developing bias voltage correction step 
(corretion voltage) for toner cartridge life
HV
Number of corrections of high density image 
density
HT
Number of corrections of half-tone image 
density
44
-12
Purpose
Adjustment/Setting/Operation data output, check 
(display, print)
Function 
(Purpose)
Used to check the sampling toner image patch density 
data in the image forming section correction (high-
density correction) (process correction). This simulation 
allows to check if the correction operation is performed 
normally.)
Section
Process (Photoconductor, developing, transfer, 
cleaning)
Item
Data
Operation data (Machine conditions)
Operation/
Procedure
The [TARGET] key and the [PATCH] key are used to 
select the display of the correction target level of each 
color and the toner image patch density sampling data.
Display
Content
CARB DATA
Color image density sensor output level when the 
calibration plate is detected by the basis of the color 
image density sensor LED current adjustment 
value.
ID (YMC)
Actual target density level in high density image 
correction
ID (K)
Actual target density level in high density image 
correction
n-1
Toner patch density (previous patch of nth patch 
data) in high density image correction (Center 
voltage - 50v) (n = 1 to 10))
n-2
Toner patch density (Medium patch of nth patch 
data) in high density image correction  (Center 
voltage) (n = 1 to 10))
n-3
Toner patch density (following patch of nth patch 
data) in high density image correction  (Center 
voltage + 50v) (n = 1 to 10))
Display
Content
44
-13
Purpose
Adjustment
Function 
(Purpose)
Color image density sensor adjustment (Adjustment by 
the adjustment jig)
Section
Process (Transfer)
Operation/
Procedure
1. Open the front cover of the machine. 
2. Install the color image density sensor adjustment jig 
to the transfer unit frame, and close the left cabinet. 
3. With the front cover of the machine open  (cover 
open/close switch OFF), turn on the power. 
4. Enter the SIM44-13 mode.
5. Close the front cover of the machine.
6. Press the [EXECUTE] key.
Adjustment is performed automatically. After 
completion of adjustment, the result is displayed and 
the [EXECUTE] key display returns to the original 
state. 
7. Remove the color image density sensor adjustment 
jig.
Display
Content
Min 
Value
Max 
Value
Default 
value
A
PCS_C 
CARB ADJ
Color image density 
sensor LED current 
adjustment target value
1
255
108
B
PCS_C 
DARK
Color image density 
sensor dark voltage 
level
0
255
0
C
PCS_C LED 
ADJ
Color image density 
sensor current 
adjustment value
1
255
51
44
-14
Purpose
Adjustment/Setting/Operation data output, check 
(display, print)
Function 
(Purpose)
Used to monitor the output level of the fusing 
temperature sensor, the machine temperature sensor, 
and the humidity sensor.
Section
Others
Operation/
Procedure
The fusing temperature, the fusing thermistor 
temperature, and the machine temperature and humidity 
are displayed.
Display
Content
FUSER TEMPERATURE 
CHECK HL1
Fusing temperature display Upper 
(Temperature/AD value)
FUSER TEMPERATURE 
CHECK HL2
Fusing temperature display Lower 
(Temperature/AD value)
Page of 61
Display