AR-C260 (serv.man12). (9) Test Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 38

Read Sharp AR-C260 (serv.man12) Service Manual online

AR-C260/C260M  SIMULATION  9 - 38
*2: When the image registration automatic adjustment operation is 
abnormal, it is judged as an error or not.
• After replacement of a toner cartridge
• At every 8000 copies (total of print and copy)
(When, however, 8000 copies is reached during a job, the operation 
is stopped after completion of the job.)
(Display items)
If the adjustment is not completed normally, "ERROR" is displayed.
In case of an error, the contents of the adjustment are not revised.
(Display items)
44
-2
Purpose
Adjustment
Function 
(Purpose)
Black image density sensor adjustment
Section
Process (Transfer)
Item
Operation
Operation/
Procedure
1. Press the [EXECUTE] key.
The amplifier gain adjustment of the black image density 
sensor is automatically performed. 
After completion of the adjustment, the result is 
displayed and the [EXECUTE] key display returns to the 
original state.
Display
Content
Min 
Value
Max 
Value
Default 
value
A PCS_C LED 
ADJ
Color image density sensor 
current adjustment value
1
255
51
B PCS K LED 
ADJ
Black image density 
sensor LED current 
adjustment value
1
255
51
C PCS_K GAIN
Black image density 
sensor output gain (AMP) 
adjustment value
0
15
0
D PCS_K DARK
Black image density 
sensor dark voltage level
0
255
0
E PCS_K GRND Black image density 
sensor transfer belt surface 
detection level 
0
255
0
F BELTMAX
Transfer belt surface max. 
detection level (Black 
image sensor)
0
255
0
G BELTMIN
Transfer belt surface min. 
detection level (Black 
image sensor)
0
255
0
H BELTDIF
Difference between max. 
and min. of the transfer belt 
surface detection level 
(BELTmax-BELTMIN)
0
255
0
44
-4
Purpose
Setting
Function 
(Purpose)
Image forming section correction, image density sensor 
adjustment conditions setup
Section
Process (Photoconductor, development, transfer)
Item
Picture quality
Operation/
Procedure
1. Select the item to beg set by the scroll key. 
2. Enter the set value with the 10-key, and press the 
[OK] key. (The entered value is set.)
Set all to the default values.
Display
Content
Min 
Value
Max 
Value
Default 
value
A PCS_C TARGET
Color image density 
sensor adjustment 
target value
1
255
108
B PCS_K TARGET
Black image density 
sensor adjustment 
target value
1
255
201
C LED_C OUTPUT
Initial current level in 
color image density 
sensor adjustment
1
255
51
D LED_K OUTPUT
Initial current level in 
black image density 
sensor adjustment
1
255
51
E PCS  ADJSTMENT 
LIMIT
Allowable error level 
in adjustments
1
255
2
F BELT GROUND 
DIF
Error judgment level 
for the belt surface 
detection level 
difference
1
255
255
G BIAS_CL 
STANDARD DIF
Set value (color) of 
the developing basis 
correction start 
voltage difference in 
high density image 
correction
0
255
50
H BIAS_BK 
STANDARD DIF
Set value (black) of 
the developing basis 
correction start 
voltage difference in 
high density image 
correction
0
255
75
I
BIAS PATCH 
INTERVAL
Patch forming 
developing bias 
voltage interval 
(voltage difference) in 
high density image 
correction
1
255
50
J
Y_PAT  TARGET 
ID
Base target density 
level (Y) in high 
density image 
correction
1
255
88
K M_PAT  TARGET 
ID
Base target density 
level (M) in high 
density image 
correction
1
255
95
L
C_PAT  TARGET 
ID
Base target density 
level (C) in high 
density image 
correction
1
255
94
M K_PAT  TARGET 
ID
Base target density 
level (K) in high 
density image 
correction
1
255
22
Page of 61
Display

Click on the first or last page to see other AR-C260 (serv.man12) service manuals if exist.