AR-C260 (serv.man12). (9) Test Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 39

Read Sharp AR-C260 (serv.man12) Service Manual online

AR-C260/C260M  SIMULATION  9 - 39
(Result/Detail messages list)
2. [CPY/PRN] key selected: Process control mode is displayed.
[CAD] key selected: Drawing mode is displayed. (Printer, etc.)
[OTHER] key selected: The environment area and the number of 
execution of process control are displayed.
(Displayed items)
N HV BK_GROUND 
LIMIT
Error judgment level 
for belt surface 
detection level 
difference (Allowable 
range of transfer belt 
surface detection 
level difference (mix. 
- min.) of black toner 
image patch position)
1
255
29
O PCS_C MARKET 
TARGET
Adjustment target 
value (Color image 
density sensor) when 
adjusting the primary 
LED current value by 
using the calibration 
plate in SIM44-36.
1
255
120
P PCS_C MARKET 
LED-REV
In SIM44-36, the 
toner patch density is 
read by three kinds of 
LED currents with the 
primary LED current 
adjustment value as 
the center value in 
order to obtain PCS 
C LED ADJ value. 
This is the deflection 
range of the current 
value in the above 
case. (Color image 
density sensor)
1
255
10
44
-6
Purpose
Operation test/check
Function 
(Purpose)
Used to forcibly execute the image forming section 
correction (high density process correction) (process 
correction).
Section
Process (Photoconductor, developing, transfer, 
cleaning)
Item
Operation
Operation/
Procedure
1. Press the [EXECUTE] key, and the image forming 
section correction is started. 
2. If the operation is normally completed, COMPLETE 
is displayed and the correction result becomes valid.
If the operation is not normally completed, ERROPR is 
highlighted and the detail of the trouble is displayed.
The detail of correction can be checked with SIM 44-9 
and SIM 44-12.
Result display
Content
COMPLETE
Correction is normally completed.
ERROR
An error occurred during correction. (The 
previous correction result is maintained.)
COMPULSORY 
INTERRUPTION
Compulsory interruption
Error display
Content
COLOR_SENSOR_
ADJUSTMENT_ERROR
Color image density sensor 
adjustment error
Display
Content
Min 
Value
Max 
Value
Default 
value
BLACK_GAIN_
ADJUSTMENT_ERROR
Black image density sensor gain 
adjustment error
BLACK_SENSOR_
ADJUSTMENT_ERROR
Black image density sensor 
adjustment error
BLACK_PROCON_ERROR
High-density image density 
correction (process correction) 
error (K)
CYAN_PROCON_ERROR
High-density image density 
correction (process correction) 
error (C)
MAGENTA_PROCON_ERROR
High-density image density 
correction (process correction) 
error (M)
YELLOW_PROCON_ERROR
High-density image density 
correction (process correction) 
error (Y)
CONNECTION_ERROR
Sensor-PCU PWB 
communication trouble
44
-9
Purpose
Adjustment/Setting/Operation data output, check 
(display, print)
Function 
(Purpose)
Used to check the data related to the image forming 
section correction (the corrected main charger grid 
voltage in each print mode, the developing bias voltage, 
etc.). (Used to check that correction is performed 
normally or not.)
Section
Process (Photoconductor, developing, transfer, 
cleaning)
Item
Data
Operation data (Machine conditions)
Operation/
Procedure
1. By scrolling with the scroll key, each data of the 
image forming section correction result. can be 
checked.
Display
Content
P (PROCON 
MODE)
Main charger grid voltage/developing bias 
voltage  by high  density image correction (Y, 
M, C, K)
N (NORMAL 
MODE (MIDDLE)
Actual main charger grid voltage/developing 
bias voltage (Normal, medium speed mode) 
(Y, M, C, K)
N (NORMAL 
MODE (LOW)
Actual main charger grid voltage/developing 
bias voltage (Normal, low speed mode) (Y, M, 
C, K)
N (NORMAL 
MODE (HIGH)
Actual main charger grid voltage/developing 
bias voltage (Normal, high-speed mode) (Y, 
M, C, K)
TS (TONER SAVE 
MODE)
Actual main charger grid voltage /Developing 
bias voltage (toner save high/medium/low 
speed mode) (K)
D (DRAWING 
MODE (MIDDLE)
Actual main charger grid voltage/developing 
bias voltage (Drawing, medium speed mode) 
(Y, M, C, K)
Error display
Content
Page of 61
Display

Click on the first or last page to see other AR-C260 (serv.man12) service manuals if exist.