AR-C260 (serv.man12). (9) Test Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 37

Read Sharp AR-C260 (serv.man12) Service Manual online

AR-C260/C260M  SIMULATION  9 - 37
(Display items)
(Items to be selected)
*1: When SIM 50-20 is used to adjust the image resist to the best and 
the image resist adjustment is performed under the following 
condition automatically, the best adjustment state may be 
changed. To avoid this, set the adjustment item AR to Disable.
When the adjustment item AR is set to Disable (ON), the image 
resist adjustment is automatically performed under the following 
conditions.
Normally set to ON condition.
41
-3
Purpose
Operation test/check
Function 
(Purpose)
Used to check the operation of the document size 
sensor and the related circuit. (The document size 
sensor output level can be monitored with the LCD 
display.)
Section
Others
Item
Operation
Operation/
Procedure
The detection output level of each sensor (PD1 ~ PD7) 
is displayed in real time.
The value in [ ] shown at the right of each sensor name 
is the threshold value.
PD1 – PD7 light receiving (A/D value) and threshold 
value (A/D value) range is 1 – 255. The default of the 
threshold value is 128.
43
-1
Purpose
Setting
Function 
(Purpose)
Used to set the fusing temperature in each operation 
mode.
Section
Fixing (Fusing)
Item
Operation
Operation/
Procedure
1. Select the kind of lamps and the operation mode with 
the scroll key. 
2. Enter the set value with the 10-key.
3. Press the [OK] key to set the fusing temperature set 
in procedure 2.
Display
Content
Set 
range
Default
100v 
Series
120v 
Series
200v 
Series
A
Normal paper HL1 set 
value
70 – 230
170
175
175
B
Normal paper HL2 set 
value
30 – 200
140
140
140
C
HL1 set value in ready 
state
70 – 230
165
170
170
D
HL2 set value in ready 
state
30 – 200
120
120
120
E
Heavy paper 1 HL1 set 
value
70 – 230
170
175
175
F
Heavy paper 1 HL2 set 
value
70 – 230
135
136
136
G
Heavy paper 2 HL1 set 
value
70 – 230
175
175
175
H
Heavy paper 2 HL2 set 
value
70 – 230
145
145
145
I
OHP1 HL1 set value
70 – 230
170
170
170
J
OHP1 HL2 set value
70 – 230
155
155
155
K
OHP2 HL1 set value
70 – 230
170
170
170
L
OHP2 HL2 set value
70 – 230
155
155
155
M
Envelope HL1 set value
70 – 230
180
180
180
N
Envelope HL2 set value
70 – 230
145
145
145
O
Temperature set value in 
pre-heating
70 – 200
143
143
143
P
Set temperature at which 
print is ready by heating 
up from the preheat 
mode. (Black and white 
copy mode)
70 – 200
165
165
165
Q
Set temperature at which 
the fusing motor starts 
rotation in warming up 
operation. 
70 – 200
155
155
155
R
When set to “1,” the upper 
and the lower heat rollers 
are ready for print only 
when they reach the 
specified temperature. 
(Used when abnormal 
fusing occurs under  low 
temperature environment. )
When set to “0,” the 
operation is performed in 
the normal mode. That is, 
print is ready when the 
upper heat roller reaches 
the specified temperature.)
0 –  1
0
0
0
44
44
-1
Purpose
Setting
Function 
(Purpose)
Used to set enable/disable of correction operations in 
the image forming (process) section.
Section
Process (Photoconductor, developing, transfer, 
cleaning)
Item
Operation
Operation/
Procedure
1. Select the process item to enable the operation.
2. Press the [EXECUTE] key. (The operations of all 
process items must be enabled.)
Display
Content
HV
Image forming section correction (Process correction)
(High-density image density correction)
HT
Half-tone image density correction
TC
Transfer output correction
RRM
RRM speed correction
MD
Photoconductor membrane decrease (sensitivity/
potential) correction
AR
Image resist auto adjustment *1
AR CHK
Image resist auto adjustment error judgment YES/NO *2
Display
Content
Set 
range
Default
100v 
Series
120v 
Series
200v 
Series
Page of 61
Display