Read Sharp AR-C260 (serv.man12) Service Manual online
AR-C260/C260M SIMULATION 9 - 18
(Set content)
∗
The interval time set range is 1 - 999sec. [Default: 3]
∗
The setup contents of this simulation remain unchanged until the
power is turned off. When SIM 7-1 is executed, the setup contents
are canceled.
power is turned off. When SIM 7-1 is executed, the setup contents
are canceled.
Copying is performed with the color selected in procedure 1).
When no print color is selected, the operation is made with the all
colors.
When no print color is selected, the operation is made with the all
colors.
The [EXECUTE] key is highlighted. When the adjustment value
entered in procedure 2) and the corresponding voltage is outputted.
entered in procedure 2) and the corresponding voltage is outputted.
The voltage is outputted for 30sec, then the [EXECUTE] key returns to
the normal display. When the EXECUTE key is pressed during output
of the voltage, the output is stopped and the [EXECUTE] key returns to
the normal display.
the normal display. When the EXECUTE key is pressed during output
of the voltage, the output is stopped and the [EXECUTE] key returns to
the normal display.
[AGING]
Jam detection setup
[INTERVAL]
Intermittent setup
[MISFEED DISABLE]
Jam detection YES/NO setup
[FUSING DISABLE]
Fusing operation YES/NO detection
[WARMUP DISABLE]
Warm-up saving setup
[DV CHECK DISABLE]
Developing tank detection YES/NO setup
[SHADING DISABLE]
Shading saving setup
7
-6
Purpose
Setting/Operation test/check
Function
(Purpose)
(Purpose)
Used to set the cycle of intermittent aging.
Item
Operation
Operation/
Procedure
Procedure
1. Enter the interval aging cycle time (sec) with the 10-
key pad.
2. Press [OK] key (or B/W Start key, Color Start key) to
set the entered cycle time.
7
-8
Purpose
Setting/Operation test/check
Function
(Purpose)
(Purpose)
Used to set Yes/No of warm-up time display.
Item
Operation
Operation/
Procedure
Procedure
Press the [EXECUTE] key to set the warm-up time
display.
When the [EXECUTE] key is pressed, the warm-up time
display setting is executed and the display returns to the
simulation main code entry display.
display.
When the [EXECUTE] key is pressed, the warm-up time
display setting is executed and the display returns to the
simulation main code entry display.
7
-9
Purpose
Setting/Operation test/check
Function
(Purpose)
(Purpose)
Used to check the image quality and operations of each
color.
color.
Section
Others
Item
Picture quality
Operation/
Procedure
Procedure
1. Select the color of image quantity and operation
check with the key.
2. Press the START key.
8
8
-1
Purpose
Adjustment/Operation test/check
Function
(Purpose)
(Purpose)
Used to check and adjust the operations of the
developing bias voltage of each color and the control
circuit.
developing bias voltage of each color and the control
circuit.
Section
Process
(Photoconductor, developing, transfer, cleaning)
(Photoconductor, developing, transfer, cleaning)
Operation/
Procedure
Procedure
(
The developing bias output voltage in each of the
following print modes can be adjusted and checked.)
(Adjustment range)
180 - 700 (Default: See below)
1. Select the color mode with the [K], [C], [M], or [Y] key.
2. Select the copy mode with the scroll key.
3. Enter the adjustment value with the 10-key pad.
4. Press the [EXECUTE] key.
(Adjustment range)
180 - 700 (Default: See below)
1. Select the color mode with the [K], [C], [M], or [Y] key.
2. Select the copy mode with the scroll key.
3. Enter the adjustment value with the 10-key pad.
4. Press the [EXECUTE] key.