AR-C260 (serv.man12). (9) Test Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 18

Read Sharp AR-C260 (serv.man12) Service Manual online

AR-C260/C260M  SIMULATION  9 - 18
(Set content)
The interval time set range is 1 - 999sec. [Default: 3]
The setup contents of this simulation remain unchanged until the 
power is turned off. When SIM 7-1 is executed, the setup contents 
are canceled.
Copying is performed with the color selected in procedure 1).
When no print color is selected, the operation is made with the all 
colors.
The [EXECUTE] key is highlighted. When the adjustment value 
entered in procedure 2) and the corresponding voltage is outputted. 
The voltage is outputted for 30sec, then the [EXECUTE] key returns to 
the normal display. When the EXECUTE key is pressed during output 
of the voltage, the output is stopped and the [EXECUTE] key returns to 
the normal display.
[AGING]
Jam detection setup
[INTERVAL]
Intermittent setup
[MISFEED DISABLE]
Jam detection YES/NO setup
[FUSING DISABLE]
Fusing operation YES/NO detection 
[WARMUP DISABLE]
Warm-up saving setup
[DV CHECK DISABLE]
Developing tank detection YES/NO setup
[SHADING DISABLE]
Shading saving setup
7
-6
Purpose
Setting/Operation test/check
Function 
(Purpose)
Used to set the cycle of intermittent aging.
Item
Operation
Operation/
Procedure
1. Enter the interval aging cycle time (sec) with the 10-
key pad.
2. Press [OK] key (or B/W Start key, Color Start key) to 
set the entered cycle time.
7
-8
Purpose
Setting/Operation test/check
Function 
(Purpose)
Used to set Yes/No of warm-up time display.
Item
Operation
Operation/
Procedure
Press the [EXECUTE] key to set the warm-up time 
display.
When the [EXECUTE] key is pressed, the warm-up time 
display setting is executed and the display returns to the 
simulation main code entry display.
7
-9
Purpose
Setting/Operation test/check
Function 
(Purpose)
Used to check the image quality and operations of each 
color.
Section
Others
Item
Picture quality
Operation/
Procedure
1. Select the color of image quantity and operation 
check with the key.
2. Press the START key.
8
8
-1
Purpose
Adjustment/Operation test/check
Function 
(Purpose)
Used to check and adjust the operations of the 
developing bias voltage of each color and the control 
circuit.
Section
Process 
(Photoconductor, developing, transfer, cleaning)
Operation/
Procedure
(
The developing bias output voltage in each of the 
following print modes can be adjusted and checked.)
(Adjustment range)
180 - 700 (Default: See below)
1. Select the color mode with the [K], [C], [M], or [Y] key.
2. Select the copy mode with the scroll key.
3. Enter the adjustment value with the 10-key pad.
4. Press the [EXECUTE] key.
Page of 61
Display

Click on the first or last page to see other AR-C260 (serv.man12) service manuals if exist.