Read Sharp AR-C170 (serv.man28) Service Manual online
AR-C170M TROUBLESHOOTING 11 - 24
Main
code
code
Sub
code
Title
Main power switch abnormality
detection
detection
L8
04
Display
Lamp/Message
Phenomenon Detail
Though the PCU program is
operating (the power is
supplied), the main power
switch OFF is detected.
operating (the power is
supplied), the main power
switch OFF is detected.
Section
—
Case 1
Cause
Main power switch trouble
Check &
Remedy
Remedy
Replace the main power
switch.
switch.
Case 2
Cause
Power supply unit trouble
Check &
Remedy
Remedy
Replace the power supply
unit.
unit.
Case 3
Cause
Harness trouble
Check &
Remedy
Remedy
Check connection of the
harness and the connector.
harness and the connector.
Main
code
code
Sub
code
Title
RIC copy inhibit signal reception
PF
00
Display
Lamp/Message
Phenomenon Detail
The copy inhibit signal from
RIC (host) is received.
RIC (host) is received.
Section
—
Case 1
Cause
Depends on a judgment by
the host.
the host.
Check &
Remedy
Remedy
Make notification to the
host. Use SIM 27-1 to
ignore.
host. Use SIM 27-1 to
ignore.
Main
code
code
Sub
code
Title
ICU-OPE communication trouble
(ICU/OPE detection)
(ICU/OPE detection)
U0
00
Display
Lamp/Message
Phenomenon Detail
Communication
establishment error,
framing/parity/protocol error.
ROM version phase shift.
establishment error,
framing/parity/protocol error.
ROM version phase shift.
Section
—
Case 1
Cause
Disconnection of the
operation panel
communication connector
of the ICU/MFP PWB,
harness trouble between
the ICU PWB and the MFP
PWB.
operation panel
communication connector
of the ICU/MFP PWB,
harness trouble between
the ICU PWB and the MFP
PWB.
Check &
Remedy
Remedy
Check the connector and
the harness between the
ICU PWB and the MFP
PWB.
the harness between the
ICU PWB and the MFP
PWB.
Case 2
Cause
ICU/MFP PWB trouble
Check &
Remedy
Remedy
Check grounding of the
machine.
Replace the ICU PWB or
the MFP PWB.
machine.
Replace the ICU PWB or
the MFP PWB.
Case 3
Cause
When the OPE-ROM
without security functions is
installed for the ICU-ROM
with security kit functions.
without security functions is
installed for the ICU-ROM
with security kit functions.
Check &
Remedy
Remedy
Check the ROM version,
and replace it if necessary.
and replace it if necessary.
Main
code
code
Sub
code
Title
FAX battery abnormality
U1
01
Display
Lamp/Message
Phenomenon Detail
FAX backup SRAM battery
voltage fall
voltage fall
Section
FAX
Case 1
Cause
Battery life
Check &
Remedy
Remedy
Check to insure that the
battery voltage is about
2.5V or above.
battery voltage is about
2.5V or above.
Case 2
Cause
Battery circuit abnormality.
Check &
Remedy
Remedy
Check the battery circuit.
Main
code
code
Sub
code
Title
RTC read trouble
U1
02
Display
Lamp/Message
Phenomenon Detail
Abnormal value is read from
the RTC on the ICU PWB.
the RTC on the ICU PWB.
Section
—
Case 1
Cause
RTC circuit abnormality
Check &
Remedy
Remedy
Set the time again with the
key operation, and check
that time advances
properly.
Check the RTC circuit.
key operation, and check
that time advances
properly.
Check the RTC circuit.
Case 2
Cause
Battery voltage fall. Battery
circuit abnormality.
circuit abnormality.
Check &
Remedy
Remedy
Check to insure that the
battery voltage is about
2.5V or above. Check the
battery circuit.
battery voltage is about
2.5V or above. Check the
battery circuit.
Main
code
code
Sub
code
Title
EEPROM read/write error (ICU
detection)
detection)
U2
00
Display
Lamp/Message
Phenomenon Detail
EEPROM version error
EEPROM write error
EEPROM write error
Section
—
Case 1
Cause
EEPROM trouble.
EEPROM is not initialized.
EEPROM is not initialized.
Check &
Remedy
Remedy
1. Check that the EEPROM
is properly set.
2. Use SIM 16 to cancel the
error.
Case 2
Cause
ICU PWB EEPROM access
circuit trouble
circuit trouble
Check &
Remedy
Remedy
1. To prevent against
deletion of the counter
data and the adjustment
data, record them with
the simulation. (When a
printer option is installed,
use SIM 22-1 to record
the counter data and the
adjustment data.)
data and the adjustment
data, record them with
the simulation. (When a
printer option is installed,
use SIM 22-1 to record
the counter data and the
adjustment data.)
2. Replace the ICU PWB.
3. Use SIM 16 to cancel the
3. Use SIM 16 to cancel the
error.
Click on the first or last page to see other AR-C170 (serv.man28) service manuals if exist.