AR-C170 (serv.man28). Troubleshooting - Sharp Copying Equipment Service Manual (repair manual). Page 25

Read Sharp AR-C170 (serv.man28) Service Manual online

AR-C170M  TROUBLESHOOTING  11 - 25
Main 
code
Sub 
code
Title
EEPROM check sum error (ICU 
detection)
U2
11
Display
Lamp/Message
Phenomenon Detail
EEPROM (ICU) check sum 
error
Section
Case 1
Cause
EEPROM trouble
Check & 
Remedy
1. Check that the EEPROM 
is properly set.
2. Use SIM 16 to cancel the 
error.
Case 2
Cause
Control circuit freeze by 
noises.
ICU PWB EEPROM access 
circuit trouble.
Check & 
Remedy
1. To prevent against 
deletion of the counter 
data and the adjustment 
data, record them with 
the simulation. (When a 
printer option is installed, 
use SIM 22-1 to record 
the counter data and the 
adjustment data.)
2. Replace the ICU PWB.
3. Use SIM 16 to cancel the 
error.
Main 
code
Sub 
code
Title
FAX backup SRAM memory check 
sum error
U2
22
Display
Lamp/Message
Phenomenon Detail
FAX backup SRAM 
memory check sum error
Section
FAX
Case 1
Cause
SRAM trouble
Check & 
Remedy
Initialize the one-touch dial 
and the FAX soft switch 
registered in the SRAM. 
Cancel the trouble with SIM 
16.
Case 2
Cause
Control circuit freeze by 
noises.
Access circuit trouble.
Check & 
Remedy
Replace the FAX PWB. Use 
SIM 16 to cancel the error.
Main 
code
Sub 
code
Title
Production No. data discrepancy 
U2
30
Display
Lamp/Message
Phenomenon Detail
The production No. 
recorded in the PCU differs 
from that recorded in the 
ICU.
Section
Case 1
Cause
EEPROM is not exchanged 
when replacing the PCU/
ICU PWB.
Check & 
Remedy
Check that the EEPROM is 
properly installed. When 
replacement, check that the 
EEPROM before 
replacement is inserted to 
the board after 
replacement.
Main 
code
Sub 
code
Title
EEPROM read/write error (SCN)
U2
80
Display
Lamp/Message
Phenomenon Detail
EEPROM version error
EEPROM write error
Section
Case 1
Cause
EEPROM trouble, Insertion 
of EEPROM which is not 
initialized or defective.
Check & 
Remedy
1. Check that the EEPROM 
is properly inserted.
2. Use SIM 16 to cancel the 
error.
Case 2
Cause
SCN PWB EEPROM 
access circuit trouble
Check & 
Remedy
1. To prevent against 
deletion of the counter 
data and the adjustment 
data, record them with 
the simulation. (When a 
printer option is installed, 
use SIM 22-1 to record 
the counter data and the 
adjustment data.)
2. Replace the SCN PWB.
3. Use SIM 16 to cancel the 
error.
Main 
code
Sub 
code
Title
Adjustment value check sum error 
(SCN)
U2
81
Display
Lamp/Message
Phenomenon Detail
EEPROM (SCN) check sum 
error
Section
Case 1
Cause
EEPROM trouble
Check & 
Remedy
1. Check that the EEPROM 
is properly inserted.
2. Use SIM 16 to cancel the 
error.
Case 2
Cause
SCN PWB EEPROM 
access circuit trouble
Check & 
Remedy
1. To prevent against 
deletion of the counter 
data and the adjustment 
data, record them with 
the simulation. (When a 
printer option is installed, 
use SIM 22-1 to record 
the counter data and the 
adjustment data.)
2. Replace the SCN PWB.
3. Use SIM 16 to cancel the 
error.
Page of 28
Display

Click on the first or last page to see other AR-C170 (serv.man28) service manuals if exist.