AR-C170 (serv.man28). Troubleshooting - Sharp Copying Equipment Service Manual (repair manual). Page 26

Read Sharp AR-C170 (serv.man28) Service Manual online

AR-C170M  TROUBLESHOOTING  11 - 26
Main 
code
Sub 
code
Title
EEPROM read/write error (PCU)
U2
90
Display
Lamp/Message
Phenomenon Detail
EEPROM version error
EEPROM write error
Section
Case 1
Cause
EEPROM trouble,
Insertion of EEPROM which 
is not initialized or defective.
Check & 
Remedy
1. Check that the EEPROM 
is properly inserted.
2. Use SIM 16 to cancel the 
error.
Case 2
Cause
PCU PWB EEPROM 
access circuit trouble
Check & 
Remedy
1. To prevent against 
deletion of the counter 
data and the adjustment 
data, record them with 
the simulation. (When a 
printer option is installed, 
use SIM 22-1 to record 
the counter data and the 
adjustment data.)
2. Replace the PCU PWB.
3. Use SIM 16 to cancel the 
error.
Main 
code
Sub 
code
Title
Adjustment value check sum error 
(PCU)
U2
91
Display
Lamp/Message
Phenomenon Detail
EEPROM (PCU) check sum 
error
Section
Case 1
Cause
EEPROM trouble
Check & 
Remedy
1. Check that the EEPROM 
is properly inserted.
2. Use SIM 16 to cancel the 
error.
Case 2
Cause
Control circuit freeze 
caused by noises, PCU 
PWB EEPROM access 
circuit trouble
Check & 
Remedy
1. To prevent against 
deletion of the counter 
data and the adjustment 
data, record them with 
the simulation. (When a 
printer option is installed, 
use SIM 22-1 to record 
the counter data and the 
adjustment data.)
2. Replace the PCU PWB.
3. Use SIM 16 to cancel the 
error.
Main 
code
Sub 
code
Title
ADU alignment plate operation 
abnormality
U4
02
Display
Lamp/Message
Phenomenon Detail
The alignment plate does 
not move from the home 
position within 1sec when it 
must move. Return to the 
home position is not 
detected for 5sec or more.
Section
ADU
Case 1
Cause
Home position sensor 
trouble
Check & 
Remedy
Use SIM 9-2 to detect the 
home position sensor.
Case 2
Cause
Alignment plate shift motor 
trouble
Check & 
Remedy
Use SIM 9-4 to check the 
alignment plate operation.
Case 3
Cause
Disconnection of the 
harness between the ADU 
control PWB and the motor 
sensor.
Check & 
Remedy
Check connection of the 
harness between the ADU 
control PWB and the motor 
sensor.
Case 4
Cause
Alignment plate operation 
belt, gear breakage or 
improper adjustment
Check & 
Remedy
Remove the ADU, and 
check for breakage of the 
gear and the belt.
Main 
code
Sub 
code
Title
Desk communication trouble
U6
00
Display
Lamp/Message
Phenomenon Detail
Desk communication error, 
communication test error 
when turning on the power 
or after canceling the 
exclusive simulation.
Section
Desk
Case 1
Cause
Improper connection or 
disconnection of the 
connector and the harness.
Check & 
Remedy
Check the connector and 
the harness in the 
communication line.
Turn OFF/ON the power to 
cancel the error.
Case 2
Cause
Desk control PWB trouble, 
control PWB (PCU) trouble, 
malfunction caused by 
noises
Check & 
Remedy
Turn OFF/ON the power to 
cancel the error.
Page of 28