AR-C170M TROUBLESHOOTING 11 - 23
Main
code
code
Sub
code
Title
Transfer belt motor trouble
L4
07
Display
Lamp/Message
Phenomenon Detail
1. Before driving the drum,
the calibration plate is
opened with the process
control BK sensor, and
light is emitted with the
gain value of 0 and with
the light emitting quantity
fixed to 120. The
average of ten light
quantities repeats to be 5
or less for 3 times
continuously.
opened with the process
control BK sensor, and
light is emitted with the
gain value of 0 and with
the light emitting quantity
fixed to 120. The
average of ten light
quantities repeats to be 5
or less for 3 times
continuously.
2. Immediately after driving
the drum, the calibration
plate is opened with the
process control BK
sensor, and one whole
turn of the belt surface is
scanned with the gain
value of 0 and with the
light emitting quantity at
the optimum value (120
– 50). The difference
between the max. value
and the min. value of the
scanned data is 5 or
less.
plate is opened with the
process control BK
sensor, and one whole
turn of the belt surface is
scanned with the gain
value of 0 and with the
light emitting quantity at
the optimum value (120
– 50). The difference
between the max. value
and the min. value of the
scanned data is 5 or
less.
Section
Paper feed
Case 1
Cause
Transfer belt motor
connector disconnection,
defective connection of the
harness between the PCU
PWB and the transfer belt
motor
connector disconnection,
defective connection of the
harness between the PCU
PWB and the transfer belt
motor
Check &
Remedy
Remedy
Check the transfer belt
motor operation with
SIM25-1. Check the
harness and the connector
between the PCU PWB and
the transfer belt motor.
motor operation with
SIM25-1. Check the
harness and the connector
between the PCU PWB and
the transfer belt motor.
Case 2
Cause
Process control sensor
connector disconnection,
process control BK sensor
defect
connector disconnection,
process control BK sensor
defect
Check &
Remedy
Remedy
Check the process control
sensor operation with
SIM44-2. Check the
harness and the connector
between the PCU PWB and
the transfer belt motor.
sensor operation with
SIM44-2. Check the
harness and the connector
between the PCU PWB and
the transfer belt motor.
Case 3
Cause
Defective control circuit
Check &
Remedy
Remedy
Check the control circuit.
Main
code
code
Sub
code
Title
Shift motor trouble
L4
11
Display
Lamp/Message
Phenomenon Detail
When initializing the shift
motor, the change in the
shift motor home position
sensor characteristics is not
detected within the
specified time.
motor, the change in the
shift motor home position
sensor characteristics is not
detected within the
specified time.
Section
Paper feed
Case 1
Cause
Shift motor trouble,
disconnection of the
harness between the PCU
PWB and the shift motor,
control circuit trouble
disconnection of the
harness between the PCU
PWB and the shift motor,
control circuit trouble
Check &
Remedy
Remedy
Use SIM 6-1 to check the
shift motor operation. Use
SIM 30-1 to check the shift
motor home position
sensor. Check the harness
and the connector between
the PCU PWB and the shift
motor.
shift motor operation. Use
SIM 30-1 to check the shift
motor home position
sensor. Check the harness
and the connector between
the PCU PWB and the shift
motor.
Main
code
code
Sub
code
Title
Full wave signal not provided
L8
01
Display
Lamp/Message
Phenomenon Detail
The full wave signal is not
provided.
provided.
Section
—
Case 1
Cause
PCU PWB trouble
Check &
Remedy
Remedy
Replace the PCU PWB.
Case 2
Cause
Power supply unit trouble
Check &
Remedy
Remedy
Replace the power supply
unit.
unit.
Case 3
Cause
Harness trouble
Check &
Remedy
Remedy
Check connection of the
harness and the connector.
harness and the connector.
Main
code
code
Sub
code
Title
Full wave signal width abnormality
L8
02
Display
Lamp/Message
Phenomenon Detail
An abnormality of the full
wave signal frequency is
detected. (The detected
frequency is 65kHz or
above, or 45kHz or below.)
wave signal frequency is
detected. (The detected
frequency is 65kHz or
above, or 45kHz or below.)
Section
—
Case 1
Cause
PCU PWB trouble
Check &
Remedy
Remedy
Replace the PCU PWB.
Case 2
Cause
Power supply unit trouble
Check &
Remedy
Remedy
Replace the power supply
unit.
unit.
Case 3
Cause
Harness trouble
Check &
Remedy
Remedy
Check connection of the
harness and the connector.
harness and the connector.
Click on the first or last page to see other AR-C170 (serv.man28) service manuals if exist.