AR-C170M  TROUBLESHOOTING  11 - 23
Main 
code
Sub 
code
Title
Transfer belt motor trouble
L4
07
Display
Lamp/Message
Phenomenon Detail
1. Before driving the drum, 
the calibration plate is 
opened with the process 
control BK sensor, and 
light is emitted with the 
gain value of 0 and with 
the light emitting quantity 
fixed to 120. The 
average of ten light 
quantities repeats to be 5 
or less for 3 times 
continuously.
2. Immediately after driving 
the drum, the calibration 
plate is opened with the 
process control BK 
sensor, and one whole 
turn of the belt surface is 
scanned with the gain 
value of 0 and with the 
light emitting quantity at 
the optimum value (120 
– 50). The difference 
between the max. value 
and the min. value of the 
scanned data is 5 or 
less.
Section
Paper feed
Case 1
Cause
Transfer belt motor 
connector disconnection, 
defective connection of the 
harness between the PCU 
PWB and the transfer belt 
motor
Check & 
Remedy
Check the transfer belt 
motor operation with 
SIM25-1. Check the 
harness and the connector 
between the PCU PWB and 
the transfer belt motor.
Case 2
Cause
Process control sensor 
connector disconnection, 
process control BK sensor 
defect
Check & 
Remedy
Check the process control 
sensor operation with 
SIM44-2. Check the 
harness and the connector 
between the PCU PWB and 
the transfer belt motor.
Case 3
Cause
Defective control circuit
Check & 
Remedy
Check the control circuit.
Main 
code
Sub 
code
Title
Shift motor trouble
L4
11
Display
Lamp/Message
Phenomenon Detail
When initializing the shift 
motor, the change in the 
shift motor home position 
sensor characteristics is not 
detected within the 
specified time.
Section
Paper feed
Case 1
Cause
Shift motor trouble, 
disconnection of the 
harness between the PCU 
PWB and the shift motor, 
control circuit trouble
Check & 
Remedy
Use SIM 6-1 to check the 
shift motor operation. Use 
SIM 30-1 to check the shift 
motor home position 
sensor. Check the harness 
and the connector between 
the PCU PWB and the shift 
motor.
Main 
code
Sub 
code
Title
Full wave signal not provided
L8
01
Display
Lamp/Message
Phenomenon Detail
The full wave signal is not 
provided.
Section
Case 1
Cause
PCU PWB trouble
Check & 
Remedy
Replace the PCU PWB.
Case 2
Cause
Power supply unit trouble
Check & 
Remedy
Replace the power supply 
unit.
Case 3
Cause
Harness trouble
Check & 
Remedy
Check connection of the 
harness and the connector.
Main 
code
Sub 
code
Title
Full wave signal width abnormality
L8
02
Display
Lamp/Message
Phenomenon Detail
An abnormality of the full 
wave signal frequency is 
detected. (The detected 
frequency is 65kHz or 
above, or 45kHz or below.)
Section
Case 1
Cause
PCU PWB trouble
Check & 
Remedy
Replace the PCU PWB.
Case 2
Cause
Power supply unit trouble
Check & 
Remedy
Replace the power supply 
unit.
Case 3
Cause
Harness trouble
Check & 
Remedy
Check connection of the 
harness and the connector.
Page of 28