AR-BD14 (serv.man5). ARBD14-Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 24

Read Sharp AR-BD14 (serv.man5) Service Manual online

Main
Sub
Item
Content
Adjustment
code
code
range
67
11
Sets select In
signal.
SIMULATION No.67-11
 SELECT-IN SIGNAL SETTING[X]:_
     0. ON    1. OFF
INPUT SETUP VALUE AND PRESS PRINT SW
[Content] Processing of Selectin signal at the Centro port is changed. 
Normally set to the default and no need to change. 
The AR-5132 receives data from Centro only when the Centro control
signal, SelectIn, is active. 
In some personal computers, Selectin signal is not active or SelectIn signal
is not connected to the Centro cable. In such a case, SelectIn signal is not
active and the AR-5132 does not receive Centro data. 
In the above case, change this setting to "1. OFF," SelectIn signals is
forcibly driven to active in the printer controller, allowing the machine to
receive Centro data. 
When this mode is set, the following operation is made:
• 0: Selectin ON 
The Selectin signal is connected to the PC as before. Under this state, the
Selectin signal (the output signal from the PC) is controlled by the PC. If,
therefore, the Selectin signal of the PC is i the false state, the centro data
cannot be received.
• 1: Selectin OFF
The Selectin signal is forcibly made True on the PRT board. Under this state,
the Selectin signal (the output signal from the PC) is not connected with the
PC and cannot be controlled by the PC. Since the Nibble mode (as well as
the Device ID due to PnP) is controlled by the Selectin signal, if "1: Selectin
OFF" is selected, the Nibble mode is not effective. 
(a)
 Operation/display
[PRINT]:
If the entered value is valid, the current setting is updated and the screen
changes to the sub code input screen. If the entered value is not valid, the
input field is cleared and the error buzzer sounds.
If any value is not entered, no setting is made and the screen changes to
the sub code input screen.
[0-1]:
Enters new settings.
[C]:
Clears the input field.
[PAUSE]:
No setting is made and the sub code input screen is displayed.
[CA]:
The execution of the simulation is stopped and the simulation is terminated.
When the setting is changed, the newly set content becomes effective after termination of
the simulation mode. 
12
Flash program
writing.
• Initial screen
SIMULATION No.67-12
 PRINTER FLASH MEMORY PROGRAM DATA
 WRITING CHECK
 PLEASE SEND PROGRAM DATA FROM PERSONAL
 COMPUTER.
– 22 –