AR-BD14 (serv.man5). ARBD14-Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 22

Read Sharp AR-BD14 (serv.man5) Service Manual online

Main
Sub
Item
Content
Adjustment
code
code
range
67
02
Centronics port
check.
• Checking in progress
SIMULATION No.67- 2
 PRINTER CENTRO PORT CHECK
 CHECKING IN PROGRESS 
• Checking completed (Example)
SIMULATION No.67- 2
 PRINTER CENTRO PORT CHECK
 PRINTER CENTRO PORT CHECK OK
[PAUSE]KEY:END DISPLAY
[Content] The Centronics port is checked by connecting a special connector which connects
the Centronics port output and input signal wires to each other, to the Centronics
port of the PRT board. Whether the input signal is turned ON/OFF or not is
checked by turning the output signal ON/OFF. Checking is repeated 10 times. If
there is no error, OK is displayed; if there is any error, NG is displayed.
<Special tool for Centro Port Test: UKOG-0254FCZZ>
(a)
 Operation/display
[PAUSE]:
The execution of the simulation is stopped and the sub code input screen is
displayed.
[CA]:
The execution of the simulation is stopped and the simulation is terminated.
03
Adjusts
Centronics port
timing.
SIMULATION No.67- 3
 PRINTER CENTRO TIMING ADJUSTMENT
 CENTRO MODE SETTING VALUE[X]: X
   0.STANDARD
   1.IBM EPSON
   2.RESERVE
   3.CLASSIC 
 2500ns ADJ.VALUE(0~127)[XXX]: XXX
 500 ns ADJ.VALUE(0~127)[XXX]: XXX
[|]KEY:MOVE     PRINT SW:EXECUTE
[Content] The control signal timing for Centronics port reception can be changed. The cur-
rent Centronics timing is displayed and a new setting can be entered.
The Centronics mode setting is specified by IEEE1284. 
0. STANDARD (default)
0-3
1. IBM EPSON
2. RESERVE
3. CLASSIC
The 2500 ns/500 ns adjustment values are adjusted for the minimum delay time
specified by IEEE1284.
2500 ns adjustment value (default value: 63)
0-127
500 ns adjustment value (default value: 13)
0-127
Normally set to the default and no need to change.
Some personal computers use a limited control method of Centro
communication, and the Centro communication method used in the
AR-5132 may not function. In such a case, change this setting to change the
Centro communication method according to the limited control method.
When the setting is changed, the newly set content becomes effective after termination of
the simulation mode. 
– 20 –
Page of 48