AR-337. Cougar Handy Guide (Updated March'02) - Sharp Copying Equipment Handy Guide. Page 20

Read Sharp AR-337 Handy Guide online

 
AR-PB2A FLASH UPGRADE 
 
SHARP ELECTRONICS (UK) LTD 
DOCUMENT SYSTEMS GROUP
 
20 
VERSION 1C 
MARCH 2002
 
 
 
9. 
Re-enter simulation 67-14 and wait until “Ready” is again displayed on the copier. 
On the PC, now type the following command that will send the Program/Font data  
to the copier.  Press the enter button on the PC.  
 .   
Copy /b PB2_XXX.hexLpt1
 
 
Whilst the Program/Font flash memory upgrade is in progress, the “Program & Font”  
section of the copiers control panel will change from “Ready” to “Receive”, “Sum”, “Erase”, 
“Blank”, “Write” and then “verify”.  If the upgrade is successful the message will finally  
read “OK”. 
  
10. 
Press the Clear All (CA) key. 
 
If any problems are experienced an “NG” will be displayed.  If this occurs, press the 
 “CA” key and repeat the download procedure. 
 
11. 
After a successful download, turn off the copier and reset the jumper JP109 to  
pins 1-2.  This will write protect the printer board. 
 
Finally, perform simulation 22-05 in order to check that the copier is recognising the updated 
flash memory. 
 
NOTE 
If you have upgraded the Printer Board from PB2(+) to PB2A, execute Sim 67-18 
 “Flash ROM Clear” for ARNS1 range when first installed onto a Cougar 2000 model  
(eg AR407). 
 
If the PB2A has been upgraded to a later version firmware (PB2A), Do NOT re-execute 
Sim 67-18 – This will delete all e-mail & scan destination lists. 
 
 
 
Page of 54