FLASH UPGRADE - ENGINE
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS GROUP
17
VERSION 1C
MARCH 2002
If the AR-PB2A SCSI cable has not yet been fitted in the copier or you do not have a
female/female SCSI connector (available from Micro Warehouse P/N DCA4475), the
following panels must also be removed (not AR287/337/407/505/507).
Rear Top Cover
Flywheel
Plastic
Plastic
Shield
Line
Guide
2.
Without a female/female SCSI connector, connect the PCMCIA SCSI adapter
cable to the SCSI PCMCIA card in the laptop and the other end directly into the
SCSI connector on the copier’s ICU board.
cable to the SCSI PCMCIA card in the laptop and the other end directly into the
SCSI connector on the copier’s ICU board.
3.
Fit the spare ICU card (must be the same as the model that is being used) into
the IC master socket. Power up the copier and perform simulation “26-44” to enable
the SCSI socket that the Laptop is now connected to.
the IC master socket. Power up the copier and perform simulation “26-44” to enable
the SCSI socket that the Laptop is now connected to.
4.
Power down the machine and remove the OPE and PCU flash cards from the
copier. Place a flash memory card in to the writing flash card socket of the ICU Pwb.
copier. Place a flash memory card in to the writing flash card socket of the ICU Pwb.
5.
Turn on the copier and then power up the laptop computer. Run the Flash
Download program and ensure that the copier is being recognised as a SCSI device
as shown below. (Any flash update files that are in the same directory as the
“Flash5.exe” program will be displayed in the firmware box as shown below).
Download program and ensure that the copier is being recognised as a SCSI device
as shown below. (Any flash update files that are in the same directory as the
“Flash5.exe” program will be displayed in the firmware box as shown below).
6.
Select the updated flash program for the relevant flash card that you have
placed within the flash memory writing socket. In the download program, click the
“Transfer” button to update the flash memory. The download will take approximately
20 seconds. (It is recommended to flash ICU Cards with ICU firmware only, OPE Cards
with OPE firmware etc).
placed within the flash memory writing socket. In the download program, click the
“Transfer” button to update the flash memory. The download will take approximately
20 seconds. (It is recommended to flash ICU Cards with ICU firmware only, OPE Cards
with OPE firmware etc).
7.
After the upgrade has been performed the copier will need to be powered off before
the flash card can be removed from the writing socket. The same procedure can
then be performed for each of the other flash memory cards.
the flash card can be removed from the writing socket. The same procedure can
then be performed for each of the other flash memory cards.
Remember to close the “Flash5.exe” program between each flash card update.
NOTE
As the upgrade procedure uses a SCSI connection to the copier, the computer must always
be powered on after the copier. This is so that the flash download program can recognise the
SCSI device (AR copier).
If the Laptop computer is running Windows 95 or 98, “Hot Swapping” is supported.
As Windows NT does not support Hot Swapping, the Laptop will have to be powered down
between each flash card upgrade.
As the upgrade procedure uses a SCSI connection to the copier, the computer must always
be powered on after the copier. This is so that the flash download program can recognise the
SCSI device (AR copier).
If the Laptop computer is running Windows 95 or 98, “Hot Swapping” is supported.
As Windows NT does not support Hot Swapping, the Laptop will have to be powered down
between each flash card upgrade.
8.
Perform Simulation 22-05 and check that the flash versions are being recognised correctly.