AR-335 (serv.man153). 1.Change Carried Out In The Binding Method Of The AC Harness Line. 2.Measure To Alleviate Problems Of Screws That Do Not Fully Secure Properly. 3.Change In The 3P Terminal Base Harness Carried Out In Accordance With A Measure To Comply With EMI Standards. 4.Measure To Improve Conditions Of Noise. 5.Measure Carried Out To Prevent Contact With The ICU Cover. (WHITE) - Sharp Copying Equipment Technical Bulletin (repair manual). Page 4

Read Sharp AR-335 (serv.man153) Technical Bulletin online

!
3.Action:
From 1998 mid-June production.
Ref.
No.
Model
name
Version
P/G No.
Current parts
New parts
Parts name
Effec-
tive time
Inter-
change-
ability
Note
Parts code
Parts code
Price
rank
1
AR280
AR285
AR335
200V
Series
10
LBNDJ0014FCZ1
AB
Wire band
Mid-
'98/6
6
2
All
36 -7
XEBSD30P06000
XEBSE30P08000
AA
Screw
Running
change
3
*
3
200V
Series
10 -55
DHAI-2854FCZZ
DHAI-2854FC11
3P terminal base
harness
Mid-
'98/6
4
AB
Series
21
PMLT-1191FCZZ
AC
Right door molt
F
6
PMLT-1192FCZZ
Right door molt R
1
PCUSG0365FCZZ
AD
Paper delivery
unit cushion L
PCUSG0366FCZZ
AC
Paper delivery
unit cushion S
Q'ty:2
5
200V
Series
5
PSHEP4675FCZZ
ICU protect
sheet
<Interchange>
1. Interchangeable.
4. Not interchangeable.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
5. Interchangeable if replaced with same types of
related parts in use.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
6. Others.
Parts marked with “
” is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
Sharp Electronics (UK)Ltd., Technical Services Group
* Only 2 locations changed.
ICU cover EX
Inside face
ICU protect sheet:
PSHEP4675FCZZ
Attachment
standard
+0~+0.5
Double sided tape
has been attached to
the shaded section.
C side
Attachment
standard
+0~+0.5
Page of 4
Display

Download Sharp AR-335 (serv.man153) Technical Bulletin