AR-280 (serv.man12). AR280 285 335 Service Manual-Simulation Codes - Sharp Copying Equipment Service Manual (repair manual). Page 117

Read Sharp AR-280 (serv.man12) Service Manual online

68
68 - 1
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of infrared communication I/F (Zaurus link) and the related circuit. (Target models:
AR-F230/S280/F280S/F280R/S330)(Japan models only)
Section
Interface
Item
Operation
Operation/
Procedure
Press the [EXECUTE] key.
The following checks are performed sequentially.
1.  ASK/IrDA modulation LSI oscillation test
2.  ASK modulation /IrDA modulation select test
3. ASK9600bps send/receive test
4. ASK19200bps send/receive test
5. IrDA9600bps send/receive test
6. IrDA115Kbps send/receive test
After completion of checking, if there is no abnormality, OK is displayed. If there is any abnormality, NG is displayed.
Note
Japan only
69
69 - 1
Purpose
Setting
Function
(Purpose)
Used to set the A2 copy unit functions.  (Target models: AR-F230/S280/F280S/F280R/S330/280/285/335)
Section
ICU
Item
Specifications
Operation mode (Common)
Operation/
Procedure
1. Enter the number corresponding to the A2 copy board connection state.
2. Press the [OK] key.
The content entered in procedure 1 is set.
Set to 1 when connecting the A2 copy board.
Note
8 – 115
Page of 118