53 - 2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the optical sensor sensitivity in the ADF/RADF. (Target models:
AR-F230/S280/F280R/S330/280/285/335)
Section
ADF/RADF/UDH/SPF
Item
Operation
Operation/
Procedure
1. The sensor names are displayed. Select the sensor to be adjusted with the key.
2. Press the [EXECUTE] key.
The adjustment of the sensor selected in procedure 1 is started. During execution of the adjustment, the [EXECUTE] key
is highlighted. If the EXECUTE key is pressed under this state, the adjustment can be interrupted.
After completion of the adjustment, the COMPLETE display is shown.
REGIST (DFD) Resist sensor
TIMING (DTD) Timing sensor
REVERSE (RDD) Paper exit/reverse sensor
Note
60
60 - 1
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation (read/write) of ICU. (SIMM MEMORY/ONBOARD MEMORY)
Section
ICU
Item
Operation
Operation/
Procedure
1. Press the [EXECUTE] key to check the read/write operations.
2. After completion of the read/write operation check, the check result is displayed with OK or NG.
Note