AR-235/275 ADJUSTMENTS - 4
Setup of various copy conditions: Similar to the normal copy mode.
<Adjustment specification>
(6) Left edge void area adjustment
Note: Before  performing  this  adjustment,  be  sure  to  check  that  the
paper off center adjustment (SIM 50-10) is completed.
1) Set a test chart (UKOG-0089SCZZ) on the document table.
2) Select a paper feed port and make two copies.
Compare  the  second  copy  and  the  test  chart.  If  necessary,  per-
form the following adjustment procedure.
The first copy does not show the void. Be sure to check the second
copy.
3) Execute SIM 50-1.
Select  the  mode  with  the  arrow  keys,  enter  the  adjustment  value
with the 10-key, and press the [OK] key.
Pressing the [START] key makes a print.
Pressing the [RETURN] key returns to the mode selection.
Setup of various copy conditions: Similar to the normal copy mode.
<Adjustment specification>
(7) Main scanning direction (FR direction) distortion 
balance adjustment
1) Remove the OC glass and the right cabinet.
2) Loosen the copy lamp unit wire fixing screw.
Display 
items
Content
Setting 
range
Default
1:BYPASS
Manual feed
1-99
50
2:TRAY1
1st cassette
3:TRAY2
2nd cassette
4:TRAY3
3rd cassette
5:TRAY4
4th cassette
6:DUPLEX
Back print
Adjustment 
mode
SIM
Set value
Spec value
Setting 
range
Paper off 
center
50-10
-2
Add 1: 0.127mm 
shift to R side.
Reduce 1: 
0.127mm shift to L 
side.
Single: 
Center 
±2.0mm
1 – 99
Second 
print surface 
off-center
50-10
-6
Duplex: 
Center 
±2.5mm
(Initial screen)
(Input screen)
(Executing screen)
Display items
Content
Setting 
range
Default
1:RRC-A
Original scan start position 
adjustment
1-99
43
2:RRC-B
RRC cancel adjustment 
(Main cassette)
1-99
18
3:RRC-MANUAL
RRC cancel adjustment 
(Manual feed cassette)
1-99
18
4:RRC-OPTION
RRC cancel adjustment 
(Option cassette)
1-99
18
5:RRC-DUPLEX
RRC cancel adjustment 
(back of the machine)
1-99
18
6:DEN-B
Rear edge void adjustment
1-99
30
7:DEN-B-DUP
Rear edge void adjustment 
(Duplex)
1-99
50
8:SIDE VOID
Left edge void adjustment 
(First print surface)
1-99
18
9:SIDE VOID-DUP
Left edge void adjustment 
(Duplex)
1-99
18
10:LOSS(OC)
Image loss quantity 
adjustment
1-5
3
Sim50-1 LEAD EDGE
1:RRC-A          
43
2:RRC-B          18
3:RRC-MANUAL     18
1/4  [  1- 99]   
43
Adjustment 
mode
SIM
Set value
Spec 
value
Setting 
range
Left edge void
50-1-
8
1 step: 0.127mm 
shift
0.5 – 4mm
1 – 99
2)
1)
1)
3)
5)
1)
1)
4)