AL-840 (serv.man6). AL800 840 Service Manual-Adjustments - Sharp Copying Equipment Service Manual (repair manual). Page 14

Read Sharp AL-840 (serv.man6) Service Manual online

5) Select the left void area adjustment with the copy picture quality
mode select key. 
(The currently set adjustment value is displayed on the copy
quantity display.)
Adjustment
mode
Adjustment mode display
(LIghting)
Note
Main scanning
direction image
position
Photo copy mode lamp
Main scanning
direction image
position (SPF
mode)
Auto/Photo/Text copy
mode lamp 
Left void area
Auto copy mode lamp
Right void area
Manual copy mode lamp
6) Change the set value and press the start button. 
(The adjustment value is stored and a copy is made.)
When the set value is increased, the void area is increased.
When the set value is decreased, the void are is decreased.
When the void area is changed by 1, the void are is changed by
0.1 mm. 
Repeat procedurs 4) 
 6) until the left void are is within the
specified range. 
7) Select the right void area adjustment with the copy picture quality
mode select key. 
(The currently set adjustment value is displayed on the copy
quantity display.)
Adjust the right void area in the same manner as the left void area
adjustment. 
*
Troubles caused by improper work
1) If the void area is less than the specified level, the transfer roller,
the fusing roller, the separation pawl, and the paper transport
section are dirtied with toner.
As a result, print paper is dirtied and paper jams are generated.
*
Necessary tools
Name
Scale
Parts code/Price rank
ADJ M6
Image process (high voltage) power
adjustment
Content
Preliminary 
work
After-
work
JOB No
JOB No
ADJ M6
Image process
(high voltage)
power adjustment
ADJ 1
Charging voltage
adjustment
ADJ M1
ADJ 2
Developing bias
voltage
adjustment/check
ADJ M1
*
Location
ADJ 1
Charging (main charger) voltage
adjustment
*
Adjustment value
Range (MIN)
–1050 V
Range (MAX)
–1200 V
Standard value
–1100 V
Default
–1100 V
*
Program used
Test command (Simulation)
MODE
Normal
MAIN CODE
8
SUB CODE
2
*
Execution condition (time)
Enforcement
time
JOB No
Content
S 009/Ua 004
When replacing the High
voltage/motor drive PWB unit
Cycle
Condition
Print (copy) density is too dark
or too light. Though copy
density adjustment is executed
with the Test command
(simulation) 46-1, satisfactory
denstiy cannot be obtained.
*
Work content
1) Connect between the power PWB and the PCU PWB, the high
voltage/motor drive PWB unit and the operation unit with har-
nesses.
2) Manually turn on the cover switch and turn on the power.
3) Execute SIM 8-2. (The charging voltage (main charer) is out-
putted.)
4) Measure the charging (main charger) voltage with a digital multi-
meter (effective value meter, input impednce 1000M
 or above).
Adjust VR801 so that the output voltage is –1050 
 –1200 V.
Before measurement, connect the capacitor and the diode to the
tip of the digital multi-metar as shown below.
ADJM7/ADJ2(VR802)
ADJM7/ADJ1(VR801)
7 – 14
Page of 19
Display