AL-840 (serv.man6). AL800 840 Service Manual-Adjustments - Sharp Copying Equipment Service Manual (repair manual). Page 9

Read Sharp AL-840 (serv.man6) Service Manual online

9) Measure the length of the copied scale image and calculate the
main scanning direction magnification ratio.
Main scanning direction magnification ratio = Copy image dimen-
sion/Original dimension 
×
 100%
10) Check if the copy magnification ratio is within the specified range
(100 
±
 1%).
If the copy magnification ratio is within the specified range, the
adjustment is completed.
If not, perform the following procedures.
(When the copy magnification ratio is over 100 
±
 1.0% with SIM
48-1 main scanning direction (manual) adjustment mode copy
magnification ratio is 50)
11) Change the CCD unit fixing position and repeat procedures 7) 
11).
*
Troubles caused by improper work
1) Never touch the other screws than the CCD unit fixing screw.
If the other screws are touched, insufficient resolution, image dis-
tortion, etc. may re resulted, which cannot be adjusted.
*
Preliminary work
JOB No
Content
ADJ M2/ADJ3
Copy sub scanning direction distortion
adjustment
*
After-work
JOB No
Content
ADJ M3/ADJ 2
Sub scanning direction copy
magnification ratio
*
Necessary tools
Name
Scale
Parts code/Price rank
Name
Test chart (resolution check chart)
Parts code/Price rank
UKOG-0089CSZZ
*
Note
With the SIM 48-1 adjustment value set to 50, change the CCD unit
fixing position. If the copy magnification ratio is adjusted within the
specified range (100 
±
 1.0%), focus is adjusted as a result. (The
specified resolution is obtained.)
If the copy magnification ratio is within the specified range (100 
±
1.0%) with the SIM 48-1 adjustment value set to 50, but if the
specified resolution is not obtained, perform the following procedures.
1) Set the SIM 48-1 adjustment value to 50.
2) Change the CCD unit fixing position so that the specified resolu-
tion is obtained.
At that time, the main scanning direction copy magnification ratio
may be outside the specified range (100 
±
 1.0%).
3) Change the adjustment value of SIM 48-1 to adjust so that the
main scanning direction copy magnification ration is in the
specified range (100 
±
 1.0%).
ADJ 2
Sub scanning direction copy
magnification ratio adjustment
*
Adjustment value
(Test command (et value))
Range (MIN)
0
Range (MAX)
99
Standard value
50
Default
50
(Sub scanning direction copy magnification ratio)
Copy magnification ratio
display value
Actual copy magnification ratio
100%
Within 
±
 1.0% of the displayed
copy magnification ratio
*
Program used
Test command (Simulation)
MODE
Normal
MAIN CODE
48
SUB CODE
1
*
Execution condition (time)
Enforcement
time
JOB No
Content
S 004
When any part in the scanner
(reading) section is
disassembled or replaced.
ADJ M3/
ADJ 1
When the main scanning
direction copy magnification
ratio is adjusted.
S 009/Ua 002
When the MCU PWB is
replaced
In case of U2 trouble
Cycle
Condition
When the sub scanning
direction copy magnification
ratio is not within the specified
range.
*
Necessary condition
1) The copy image distortion is within the specified range.
2) The copy image is free from deflection.
3) The copy image density is within the specified range.
4) The main scanning direction coy magnification ratio is within the
specified range.
*
Work content
1) Enter the simulation 48-1 mode.
2) Select the sub scanning direction adjustment mode with the copy
picture quality mode select key.
(The currently set copy magnification ratio adjustment value is
displayed on the copy quantity display.)
100
110
120
130
150
140
mm
1/2mm
JAPAN
HARDDENCD
STAINLESS
Shizuoka
100
110
120
130
150
140
mm
1/2mm
JAPAN
HARDDENCD
STAINLESS
Shizuoka
110
10
20
10
20
(When a 100mm scale is used as the original)
Original (scale)
Reference
Comparison point
Copy
Note: To minimize the reading errer, measure at scale of 110 with
7 – 9
Page of 19
Display

Click on the first or last page to see other AL-840 (serv.man6) service manuals if exist.