AL-840 (serv.man6). AL800 840 Service Manual-Adjustments - Sharp Copying Equipment Service Manual (repair manual). Page 15

Read Sharp AL-840 (serv.man6) Service Manual online

*
Troubles caused by improper work
1) Copy (print) defective (Insufficient density, background copy, dirt,
etc.)
2) The copy density cannot be adjusted in the proper range with SIM
46-1.
3) The photoconductor is damaged.
*
After-work
JOB No.
Content
ADJ M1
Copy density adjustment
*
Necessary tools
Name
Digital multi-meter/High voltage probe
Parts code/Price rank
Note
Internal impedance 1000 or above,
effective value measurement
Recommendable unit:
(FLUKE 87/FLUKE 80K-40)
Name
Diode
Parts code/Price rank
VHDSV03///-1
Note
Other type withstand voltage of 2KV or
above can be used instead.
Name
Capacitor
Parts code/Price rank
VCKYQ3FB102K
Note
Other type withstand voltage of 3KV
with 1000pF can be used instead.
*
Note
1) Use a digital multi-meter (effective value meter, internal im-
pedance of 1000M
 or above).
Connect the capacitor and the diode to the tip of the digital multi-
meter for measurement. If the above condition are not satisfied,
the proper measurement of voltage cannot be made.
2) Since a high voltage is outputted, be careful of electric shock.
ADJ 2
Developing bias voltage adjustment
*
Adjustment value
Range (MIN)
–305 V
Range (MAX)
–315 V
Standard value
–310 V
Default
–310 V
*
Program used
Test command (Simulation)
MODE
Normal
MAIN CODE
8
SUB CODE
2
*
Execution condition (time)
Enforcement
time
JOB No
Content
S 009/Ua 004
When replacing the high
voltage/motor drive PWB unit
Cycle
Condition
1) Print (copy) density is too
dark or too light.
Though copy density
adjustment is executed with
the Test command
(simulation) 46-1,
 satisfactory denstiy cannot
be obtained. 
2) Ghost is generated.
*
Work content
1) Connect between the power PWB and the PCU PWB, the high
voltage/motor drive PWB unit and the operation unit with har-
nesses.
2) Manually turn on the cover switch and turn on the power.
3) Execute SIM 8-2. (The developing bias voltage is outputted.)
4) Measure the developing bias voltage with the digital multi-meter
(effective value meter).
Adjust VR802 so that the output voltage is –310 
±
 5V.
7 – 15
Page of 19
Display

Click on the first or last page to see other AL-840 (serv.man6) service manuals if exist.