AL-840 (serv.man6). AL800 840 Service Manual-Adjustments - Sharp Copying Equipment Service Manual (repair manual). Page 17

Read Sharp AL-840 (serv.man6) Service Manual online

*
Troubles caused by improper work
1) Copy (print) defective
(Insufficient density, background copy, dirt, etc.)
(Ghost)
2) The copy density cannot be adjusted with SIM 46-1.
*
Necessary tools
Name
Digital multi-meter/High voltage probe
Parts code/Price rank
Note
Internal impedance of 1000M
 or
above, efffective value measurement
(Recommendable unit: FLUKE 87/
FLUKE 80K-40)
*
Note
1) Use a digital multi-meter (effective value meter, internal im-
pedance of 1000M
 or above).
If the above conditiosn are not satisfied, the proper measurement
of voltage cannot be made.
2) Since a high voltage is outputted, be careful of electric shock.
ADJ M7
Fusing temperature adjustment
Content
ADJ M7 Fusing temperature
adjustment
ADJ 1
Fusing temperature
adjustment within 20
sheets of continuous print 
ADJ 2
Fusing temperature
adjustment after 20 sheets
of continuous print
ADJ 1
Fusing temperature adjustment within 20
sheets of continuous printing
ADJ 2
Fusing temperature adjustment after 20
sheets of continuous printing
*
Adjustment value
(Test command (simulation) adjustment value)
Fusing temperature adjustment within 20 sheets of continuous print-
ing
Range (MIN)
1 (155°C)
Range (MAX)
5 (175°C)
Standard value
0 (160°C)
Default
0 (160°C)
Fusing temperature adjustment after 20 sheets of continuous printing
Range (MIN)
1 (150°C)
Range (MAX)
5 (175°C)
Standard value
2 (155°C)
Default
2 (155°C)
(Adjustment value)
Fusing temperature adjustment within 20 sheets of continuous print-
ing
Adjust to 160°C.
Fusing temperature adjustment after 20 sheets of continuous printing
Adjust to 155°C.
*
Program used
Fusing temperature adjustment within 20 sheets of continuous print-
ing
Test command (Simulation)
MODE
Normal
MAIN CODE
43
SUB CODE
1
Fusing temperature adjustment after 20 sheets of continuous printing
Test command (Simulation)
MODE
Normal
MAIN CODE
43
SUB CODE
4
*
Execution time
Enforcement
time
JOB No
Content
S 009/Ua 002
When replacing MCU PWB
In case of U2 trouble
Cycle
Condition
*
Job content
(Fusing temperature adjustment within 20 sheets of continuous print-
ing)
1) Enter SIM 43-1 mode.
(The currently set code of the fusing temperature adjustment
within 20 sheets of continuous printing is displayed.)
2) Set the adjustment value to 0 (160°C) and press the start button.
(Fusing temperature adjustment after 20 sheets of
continuous printing)
1) Enter SIM 43-4 mode.
(The currently set code of the fusing temperature adjustment after
20 sheets of continuous printing is displayed.)
2) Set the adjustment value to 1 (155°C) and press the start button.
*
Trouble caused by improper work
1) Fusing abnormality
2) Fusing section parts damage
3) Paper jam
*
Note
Be sure to set to the standard value. If not a trouble may occur.
7 – 17