CHAPTER 6. DISASSEMBLY AND ASSEMBLY
PN-V602 DISASSEMBLY AND ASSEMBLY
 6 – 3
3 ) Open the clamp. Disconnect the connector at two positions. Remove four screws 
A (M3 x 6, Silver), and remove the fan assembly. Remove four
screws 
B (M3 x 28, Silver) and remove the fan.
CAUTION
NOTE FOR ASSEMBLY
n
When installing, be careful of the fan direction. Do not cover the convex positioning section.
n
When replacing the fan, be careful not to pinch the harness.
SCREW TIGHTENING TORQUE
n
0.55 - 0.65N•m
3. EXPANSION COVER
1 ) Unscrew 8pcs of screws (M3 x 4 (black)), and remove the Expansion cover.
CAUTION
SCREW TIGHTENING TORQUE
n
0.7 - 0.9N•m
Slit
Slit
FAN
FAN
Clamp
Clamp
FAN Assy
FAN Assy
Mark
Mark
B
Screw
x 4
A
Screw
x 4
Screw x 8