CHAPTER 6. DISASSEMBLY AND ASSEMBLY
PN-V602 DISASSEMBLY AND ASSEMBLY
 6 – 2
2. IDP FAN
1 ) Unscrew 6pcs of screws (M3 x 8 (silver)), and remove the Fan cover.
CAUTION
SCREW TIGHTENING TORQUE
n
0.55 - 0.65N•m
2 ) Disconnect 8 connectors. Unscrew 16pcs of screws (M3 x 28 (silver)), and remove the Fan.
CAUTION
NOTE FOR ASSEMBLY
n
Attach it so that the label can be seen.
n
Attach the Fan with attention to the orientation so that the Fan harness can be pulled out in alignment with the engraved mark of plate.
n
Be careful of the location of the Fan fixing screw and not to drop the screw.
n
Be careful not to get the harness wire caught when replacing the Fan.
SCREW TIGHTENING TORQUE
n
0.55 - 0.65N•m
Screw x 6
Mark
Mark
Mark
Mark
Mark
Mark
FAN
Screw x 16
Page of 127