PN-E802 (serv.man3) - Sharp Monitor Service Manual (repair manual). Page 125

Read Sharp PN-E802 (serv.man3) Service Manual online

CHAPTER 6. DISASSEMBLY AND ASSEMBLY
PN-E802/E702/E602 DISASSEMBLY AND ASSEMBLY
 6 – 22
2 ) Disconnect four connectors, remove one screw 
A (M4 x 6 SW+W, Silver), and remove the AC switch. Remove two screws B (M3 x 8 counter-
sunk, Black), and remove the AC inlet cable.
CAUTION
SCREW TIGHTENING TORQUE
n
Screw 
A: 0.9 - 1.1N•m
n
Screw 
B: 0.7 - 0.9N•m
■ PN-E702/E602
1 ) Disconnect four connectors, remove one screw 
A (M4 x 6, Silver), and remove the AC switch. Remove two screws B (M3 x 6 countersunk,
Black), and remove the AC inlet cable. 
CAUTION
SCREW TIGHTENING TORQUE
n
Screw 
A: 0.9 - 1.1N•m
n
Screw 
B: 0.7 - 0.9N•m
Confirm that the circle (
o
) is on 
the left side and it is in the OFF.
When attaching, ensure that the terminals are 
oriented as indicated in the engraved mark.
Mark
Blue
Black
White
A  x 1
Screw
White
AC switch
AC inlet cable
B  x 2
Screw
A
Screw
x 1
Black
White
White
Blue
Confirm that the circle 
(o) is on the left side 
and it is in the OFF 
Screw x 2
AC Inlet Cable
AC Switch
Mark
When attaching, ensure that the 
terminals are oriented as 
indicated in the engraved mark.
Page of 127
Display