PN-E802 (serv.man3) - Sharp Monitor Service Manual (repair manual). Page 123

Read Sharp PN-E802 (serv.man3) Service Manual online

CHAPTER 6. DISASSEMBLY AND ASSEMBLY
PN-E802/E702/E602 DISASSEMBLY AND ASSEMBLY
 6 – 20
8. C-PWB UNIT
1 ) Disconnect one connector, remove four screws (M3 x 6, Silver), and remove the C-PWB cover.
CAUTION
SCREW TIGHTENING TORQUE
n
0.55 - 0.65N•m
2 ) Disconnect two connectors of the flat cable, remove six screws (M3 x 6 SW+W, Silver), and remove the C-PWB unit. 
CAUTION
SCREW TIGHTENING TORQUE
n
0.5 - 0.65N•m
9. 5V POWER SUPPLY UNIT
1 ) Disconnect two connectors, remove four screws (M3 x 6 SW+W, Silver), and remove the 5V power supply unit.
CAUTION
SCREW TIGHTENING TORQUE
n
0.55 - 0.65N•m
Screw x 4
Connector x 1
Screw x 6
Connector x 2
Screw x 4
Connector x 2