CHAPTER 6. DISASSEMBLY AND ASSEMBLY
PN-E802/E702/E602 DISASSEMBLY AND ASSEMBLY
 6 – 21
10. AC RELAY PWB
1 ) Disconnect four connectors, remove five screws (M3 x 6 SW+W, Silver), and remove the AC relay PWB.
CAUTION
SCREW TIGHTENING TORQUE
n
0.55 - 0.65N•m
11. INLET HARNESS/AC SWITCH
■ PN-E802
1 ) Remove two screws (M4 x 6, Black), and remove the AC inlet cover.
CAUTION
SCREW TIGHTENING TORQUE
n
0.9 - 1.1N•m
Screw x 5
Connector x 4
Screw x 2