UP-X500 (serv.man4). UP-X500 Service Manual - Sharp EPOS Service Manual (repair manual). Page 10

Read Sharp UP-X500 (serv.man4) Service Manual online

UP-X500U
DIagnostics Specifications
4 – 3
(2) Target Sector Read Test
[Test condition setting]
• Test area setting
•  Retry number setting (0 ~ 4)
The retry number in case of an error is set. 
•  Error Stop/Continue/1 pass
In case of an error, selection is made whether interrupt is made or not.
Also used to select whether the test is executed or not by 1 pass.
[Test contents]
The sequential read test for every one track is executed in the range set
as above.
Completion of the read test in the set range is counted as 1 pass.
The operation of this test is as shown below:
(3) Sequential Write/Read & Compare Test
[Test condition setting]
Similar to the above (2). However, the cylinder set range is 01
0
79.
[Test contents]
The worst pattern data are written into each track in all the set range.
Then perform the read/verify check. When the write/read test in the set
range in the direction of 0
0
79 cylinder is completed, it is considered
as 1 pass.
The operation of this test is as shown below:
When writing data, write different data from those originally stored.
(Worst pattern data)
Word data: There are two kinds of data: B6DBh, 6DB6h.
(4) Target Sector Write/Read-Compare Test
[Test condition setting]
Similar to the above (2). However, setting of the retry number is omitted.
[Test contents]
The write/read test in the set range is executed.
When the write/read test in the set range is completed, it is considered
as 1 pass.
The operation of this test is as shown below:
(5) Error table display
The error contents generated in procedures (1) ~ (4) are displayed for
each test item. The display items are test item, test condition, drive, cyl-
inder, head, sector, error contents, and hour/minute/second. The maxi-
mum number of display items is 50 for each test.
4-2-5. Test Display
(1) Floppy Disk Test menu display
On the above menu, use [
2
] and [
4
] keys to select a test item. Press
[ENTER] key to execute the test. When [ESC] key is pressed, the dis-
play returns to the initial menu.
(2) Sequential read only test execution display
Select an item in each position indicated with "
"
(In the above display, the item surrounded by a 
 is selected and the
value surrounded by a 
is selected.)
When, in the above display, "Pass count" is counted up (when the test
point is counted from 00.0.01 to 79.1.10, Pass count is counted up by 1)
and all the error counters of all the error kinds are not counted up
(remaining at 00000), the test is OK.
During execution of the test, when [SPACE] key is pressed, the test is
interrupted. 
During interruption of the test, when [SPACE] key is pressed, the test is
resumed. 
During execution or interruption of the test, when [ESC] key is pressed,
the display returns to the menu of (1).
Cylinder
: The cylinder number to be checked is set in the
range of 00
0
79. 
Head
: The head number to be checked is set in the range
of 0
0
1.
Sector
: The sector number to be checked is set in the range
of 00
0
18 (9).
Re-calibration
Seek to the track
to be tested
Lead test
These procedures
are repeated.
becoming
Re-calibration
Read/verify test
in all the set rage
These procedures are repeated.
becoming
Write to all the
set range.
Re-calibration
Seek to the
track to be
tested
These procedures are repeated.
becoming
Date
write
Read/
verify
Floppy Disk Drive Diagnostics
Sequential read only test
Target Sector read test
Sequential write/read & Compare test
Target sector write/read & Compare test
Error table display
ENTER:Select
ESC:Exit
:FMove
Sequential read only test
Drive_A(1.44MB)test ? [  Yes  No]
Error Kinds                  Drive_A
Cylinder scope ?
Bad command             xxxxx
Drive_A [00     79] 00 - 79
Bad Address Mark       xxxxx
Sector count ?
Drive_A [1,3,9] =  9
Error stop ?
Recalibrate error          xxxxx
Pass count = xxxxx
Test Point=CC,H,SS
TIME HH:MM:SS
Retry Count ? [0     4] =  0
[error stop  continue  1 pass]
Test Start [ Yes   No]
Test mode :  Read    Test drive : Drive_A
ESC:Exit
SPACE:Stop or Start
Error details content
(Cylinder, head, celector)
(hour : minute : sound)
Page of 75
Display

Click on the first or last page to see other UP-X500 (serv.man4) service manuals if exist.