UP-X500 (serv.man4). UP-X500 Service Manual - Sharp EPOS Service Manual (repair manual). Page 14

Read Sharp UP-X500 (serv.man4) Service Manual online

UP-X500U
DIagnostics Specifications
4 – 7
4-3-5. Test display
(1) Hard disk test menu
Select an test item with [
2
] and [
4
] keys on the above menu and press
[ENTER] key to start the test. When [ESC] key is pressed, the display
returns to the initial menu. 
(2) Drive status display execution display
The standard value of the hard disk is displayed. 
When any key is pressed, the test is terminated and the display returns
to the menu display of the previous (1).
(3) Sequential seek test execution display
Select an item in each position indicated with "
"
(In the above display, the item surrounded by a 
 is selected and the
value surrounded by a 
 is selected.)
When, in the above display, "Pass count" is counted up (when the test
point is counted from 000 to the final LBA, Pass count is counted up by
1) and all the error counters of all the error kinds are not counted up
(remaining at 00000), the test is OK.
During execution of the test, when [SPACE] key is pressed, the test is
interrupted. 
During interruption of the test, when [SPACE] key is pressed, the test is
resumed. 
During execution or interruption of the test, when [ESC] key is pressed,
the display returns to the menu of (1).
(4) Seek & read test execution display
Select an item in each position indicated with "
"
(In the above display, the item surrounded by a 
 is selected and the
value surrounded by a 
 is selected.)
When, in the above display, "Pass count" is counted up (when the test
point is counted from 000 to the final LBA, Pass count is counted up by
1) and all the error counters of all the error kinds are not counted up
(remaining at 00000), the test is OK.
The procedures to interrupt, resume, and terminate the test are the
same as those of the above (3). 
(5) Read test execution display
Similar to the above (4).
Drive type
: Hard disk drive name
Capacity
: Memory capacity of the hard disk
Cylinder number
: Max. cylinder number
Head number
: Max. head number
Sector number
: Max. sector number
Lba number
: LBA number
Firmware Ver.
: Firmware version No.
Hard Disk Drive Diagnostics
READ MODE TEST
ERROR LOGGING AREA CLEAR(DIAG)
Drive status display
Sequential seek test
Random seek test
Seek & Read test
Target Sector Read test
HD Dump test
Error LOGGING Information Display (DIAG)
Disk Controller Check test
WRITE MODE TEST
Seek  &  Write/Read-Verify test
Target Sector Write/Read-Verify test
HD Patch test
ENTER:Select
ESC:Exit
     :FMove
Error Table Display
Smart ON/OFF
Drive Status display
hard disk drive information
Drive Type     
Capacity        
Cylinder number 
Head number   
Sector number  
Press any key to exit.
:
:
:
:
:
Farm ware ver   :
Target Sector Read test
LBA range 
?
Error Kinds
Drive not ready
Retry count ?
Bad controller
[Error stop continue 1 pass]
Test Start ?[ Yes  No]
Compare error
Pass count=xxxxx
Test Point=xxxxxxxx (LBA)
[0000000-194608791]
[0-4]= 0
ESC:Exit      SPACE:Stop       Start
Error details content
or
~
~
Target Sector Read test
LBA range 
?
Error Kinds
Drive not ready
Sector count ?
Bad controller
[Error stop continue 1 pass]
Test Start ?[ Yes  No]
Compare error
Pass count=xxxxx
Test Point=xxxxxxxx (LBA)
[0000000-194608791]
[0-63]= 63
Retry count  ?
[0-4]= 0
ESC:Exit      SPACE:Stop       Start
Error details content
or
~
~
Page of 75
Display