UP-X500 (serv.man4). UP-X500 Service Manual - Sharp EPOS Service Manual (repair manual). Page 8

Read Sharp UP-X500 (serv.man4) Service Manual online

UP-X500U
DIagnostics Specifications
4 – 1
CHAPTER 4. DIAGNOSTICS SPECIFICATIONS
1. OUTLINE
This manual describes the diag specifications and operating proce-
dures of the UP-X500 series.
The main unit diag of this manual is applicable to the following models:
Main unit diag: UP-X500 series.
The diag program is supplied in the following test media:
(1) UP-X500 series service diag.
2. DIAL BOOT/TERMINATTION
The procedures to boot and terminate the diag are described below.
2-1. WITH THE MAIN POWER OFF, INSERT THE
TEST MEDIA INTO THE PC CARD SLOT. 
2-2. TURN ON THE MAIN POWER.
2-3. THE DISPLAY SHOWS THE MENU TO SELECT
WHETHER A LOG FILE IS TAKEN FOR USE
WITH THE DIAG MEDIA (PC CARD) OR NOT. 
[Do you take a LOG~ FILE on FD?]
[No Log 
0
 Take a Log]
Select 
[
No Log
]
 or 
[
Take a Log
]
 with the cursor keys, and press
[ENTER] key to execute.
When 
[
No Log
]
 is executed: No log file is made. 
When 
[
Take a Log
]
 is executed: 
A log file is made and saved on the diag media as is conventionally done. 
The current state of the media (Read/Write s a Read Only) is displayed on
the front for several seconds, and the display shifts to the next step. 
2-4. THE DIAG MAIN MENU IS DISPLAYED. 
2-5.  EACH INDIVIDUAL TEST CAN BE PERFORMED
FROM THE MAIN MENU BY KEY OPERATIONS.
(REFER TO 3. KEY OPERATIONS.)
2-6.
TO TERMINATE THE DIAG, PRESS [ESC] KEY TO
RETURN TO THE STATE WHERE NO ITEM IS
SELECTED ON THE MAIN MENU DISPLAY, AND
PRESS [FA] (F10) KEY TO GO TO THE MS-DOS
PROMPT. 
2-7. CHECK THAT THE MS-DOS PROMPT IS DIS-
PLAYED, AND TURN OFF THE MAIN POWER. 
3. KEY OPERATIONS
The key operations for execution of the diag are described below. 
4. INDIVIDUAL TEST ITEMS
(GENERAL, TEST ITEMS, TEST CON
TENTS, ERROR CONTENTS)
4-1. DRAM
4
-1-1. Outline
The DRAM test is performed.
The memory check program writes data of a certain pattern into the
DRAM, and reads data to perform comparison check and parity check.
The test memory area varies depending on the setup utility setting
(CMOS area setting). When an error occurs during test, the error infor-
mation is displayed on real time. 
4
-1-2. Jig to be used
The above jigs must be installed or removed with the power OFF.
5-1-3. Test Item
The purposes of this test are as follows:
UP-X500 Serise Diagnostics
 F1:Trouble Shooting      F2:Product Check      F3:Single P.W.B. Chec k
 [Main Unit]    UP-X500V    UP-X500U    UP-X300V    UP-X300U
 [Item]
 *Information
 *COM1/2
 *LAN
 *MCR
CURSOR:Move     ENTER:Select     F10:Diag End     F1-F3:Diag Mode change
 *VGA I/F LCD
 *Line Display
 *106 Keyboard
 *Centro I/F(AT)
 *Buzzer
 *Drawer
 *RTC
 *Floppy Disk
 *DRAM
 *Hard Disk (std)
 *PCMCIA
* Clerk
* Contactlrss Clerk
* PCP3
[F1]
: Trouble shooting
When [F1] key is pressed on the main menu, the menu is
shifted to the trouble shooting (for service repair) menu. Press
[ENTER] key to allow selection of [Item] (individual test item).
[F10]
: The display returns to the MS-DOS prompt.
With no [Item] (individual test item) selected on the main menu,
when [FA] key is pressed, the diag program is terminated and
the display returns to the MS-DOS prompt.
[ESC]
: Used to terminate, reset, and cancel selection of each individual
test item. Pressing [ESC] key more times than necessary does
not cause a problem, and it does not return to the previous
stage from the main menu.
When [F7] key is pressed 7 times continuously on the main
menu. the test media is switched to Read/Write media s a Read
Only media. This function, however, is disabled if [No Log] is
selected when booting the diag. 
[Cursor] : Used to shift to a test item and input position.
[Space]
: Used to set selection. Also used to start/stop read/write test of
the disk.
[Enter]
: Used to execute the selected item and to determine an input
item.
[BS]
: Back space
Other
: Alphanumeric input 1~0, A~F
•  UP-X500 series main unit diag execution media x 1
•  Expansion memory unit (DIMM) 
x 1
• Write/Read-Verify Test
• Error Table
Page of 75
Display

Click on the first or last page to see other UP-X500 (serv.man4) service manuals if exist.