iv. Data 04H is written into I/O address 3BEH, and data at I/O
address 379H is read. If the read data is 37H, "PE Signal OK"
and "SLCT signal OK" are displayed. If not, "PE Signal ER-
ROR" and "SLCT Signal ERROR" are displayed.
v.
Data 08H is written into I/O address 3BEH, and data at I/O
address 379H is read. If the read data is 0FH, "ERROR-Signal
OK" is displayed. If not, "ERROR-Signal ERROR" is dis-
played.
vi. Data 01H is written into I/O address 37AH, and data at I/O
address 3BDH is read. If the read data is 47H, "STROBE-Sig-
nal OK" is displayed. If not, "STROBE-Signal ERROR" is dis-
played.
vii. Data 02H is written into I/O address 37AH, and data at I/O
address 3BDH is read. If the read data is 87H, "AUTOFD-Sig-
nal OK" is displayed. If not, "AUTOFD-Signal ERROR" is dis-
played.
viii. Data 04H is written into I/O address 37AH, and data at I/O
address 3BDH is read. If the read data is 37H, "INIT-Signal
OK" is displayed. If not, "INIT-Signal ERROR" is displayed.
ix. Data 08H is written into I/O address 37AH, and data at I/O
address 3BDH is read. If the read data is 0FH, "SLCTIN-Sig-
nal OK" is displayed.
x.
Data 10H is written into I/O address 37AH to generate an
interruption. If an interruption is generated, the interruption
level is displayed. If no interruption is generated, "Interrupt
ERROR" is displayed. After confirmation of an interruption,
data 00H is written into I/O address 37AH.
xi. Data 55H is written into I/O address 378H, and data at I/O
address 3BCH is read. If the read data is 55H, the next check
is performed. If not, "DATA Bus ERROR" is displayed.
xii. Data AAH is written into I/O address 378H, and data at I/O
address 3BCH is read. If the read data is AAH, "DATA Bus
OK" is displayed. If not, "DATA Bus ERROR" is displayed.
2
Display
LPT1 Loop Check
ACK- Signal
:
PASS !! (or ERROR !!)
BUSY Signal
:
PASS !! (or ERROR !!)
PE Signal
:
PASS !! (or ERROR !!)
SLCT Signal
:
PASS !! (or ERROR !!)
ERROR- Signal
:
PASS !! (or ERROR !!)
STROBE- Signal
:
PASS !! (or ERROR !!)
AUTOFD- Signal
:
PASS !! (or ERROR !!)
INIT- Signal
:
PASS !! (or ERROR !!)
SLCTIN- Signal
:
PASS !! (or ERROR !!)
INTERRUPT
:
IRQ X (or ERROR !!)
DATA Bus
:
PASS !! (or ERROR !!)
"XX" shows the interruption level.
If LPT1 is not accessible, the display shows the following.
LPT1 Loop Check
LPT1 Channel Disabled
3
Exiting
Pressing the Esc key will exit from this check mode.
2) LPT2 Loop Check
1
Check contents
Loop check is performed to LPT2 at I/O address 278H 
 27FH.
To perform the loop check, insert an ER-A8RS to be checked to
the extension slot, insert another ER-A8RS which is operating
normally to another slot, and connect the loop cable as shown in
Fig. 3-3.  For the jumper setting on the PWB, refer to Fig. 3-5.
Fig. 3-5 Jumper pin setting
The test procedures are as follows:
i.
Data 55H is written into I/O address 278H, and the same
address is read. If the read data is not 55H, "LPT2 Disabled"
is displayed and the following procedures are not performed.
ii.
Data 01H is written into I/O address 3BEH, and data at I/O
address 279H is read. If the read data is 47H, "AC-Signal OK"
is displayed. If not, "AC-Signal ERROR" is displayed.
iii.
Data 02H is written into I/O address 3BEH, and data at I/O
address 279H is read. If the read data is 87H, "BUSY Signal
OK" is displayed. If not, "BUSY Signal ERROR" is displayed.
iv. Data 04H is written into I/O address 3BEH, and data at I/O
address 279H is read. If the read data is 37H, "PE Signal OK"
and "SLCT signal OK" are displayed. If not, "PE Signal ER-
ROR" and "SLCT Signal ERROR" are displayed.
v.
Data 08H is written into I/O address 3BEH, and data at I/O
address 279H is read. If the read data is 0FH, "ERROR-Signal
OK" is displayed. If not, "ERROR-Signal ERROR" is dis-
played.
vi. Data 01H is written into I/O address 27AH, and data at I/O
address 3BDH is read. If the read data is 47H, "STROBE-Sig-
nal OK" is displayed. If not, "STROBE-Signal ERROR" is dis-
played.
vii. Data 02H is written into I/O address 27AH, and data at I/O
address 3BDH is read. If the read data is 87H, "AUTOFD-Sig-
nal OK" is displayed. If not, "AUTOFD-Signal ERROR" is dis-
played.
viii. Data 04H is written into I/O address 27AH, and data at I/O
address 3BDH is read. If the read data is 37H, "INIT-Signal
OK" is displayed. If not, "INIT-Signal ERROR" is displayed.
ix. Data 08H is written into I/O address 27AH, and data at I/O
address 3BDH is read. If the read data is 0FH, "SLCTIN-Sig-
nal OK" is displayed.
x.
Data 10H is written into I/O address 27AH to generate an
interruption. If an interruption is generated, the interruption
level is displayed. If no interruption is generated, "Interrupt
ERROR" is displayed. After confirmation of an interruption,
data 00H is written into I/O address 27AH.
xi. Data 55H is written into I/O address 278H, and data at I/O
address 3BCH is read. If the read data is 55H, the next check
is performed. If not, "DATA Bus ERROR" is displayed.
xii. Data AAH is written into I/O address 278H, and data at I/O
address 3BCH is read. If the read data is AAH, "DATA Bus
OK" is displayed. If not, "DATA Bus ERROR" is displayed.
1
2
3
J1
9
1
0
J4
J3
1
2
3
J1
9
1
0
J4
J3
Setting ER-A8RS to be checked
Setting ER-A8RS to check
– 15 –