Serial I/O Diagnostics
 COM1 Check 
 COM2 Check
 COM3 Check
 COM4 Check
 COM5 Check
 COM6 Check
1) COM1 Check
1
Check contents
Loop back check is performed to UART at I/O address 3F8H 
3FFH. The test procedures are as follows:
i.
UART setting is made. If UART is not accessible, "COM1
Disabled" is displayed and the following procedures are not
performed.
ii.
The RTS signal is turned on/off to check the operation of the
CD signal and the CTS signals. In case of an error, "ERROR"
is displayed.
iii.
The DTR signal is turned on/off to check the operations of the
DSR signal and the RI signal. IN case of an error, "ERROR" is
displayed. If an error occurs in procedure ii or iii, the following
procedures are not performed.
iv. The baud rate is set to 19200bps asynchronous mode and
data of 256 bytes at 00H 
 FFH is sent from the SD signal
line. Data received in the RD signal line is compared with the
sent data to check if the both are identical. If the output data is
not send back within 5 sec, "ERROR" is displayed and the test
is terminated.
v.
An interrupt signal is delivered from UART and the number of
generated interrupt request signal is displayed.
2
Display
Serial I/O COM1 Check
RTS - CD
:
PASS !! (or ERROR !!)
RTS - CTS
:
PASS !! (or ERROR !!)
DTR - DSR
:
PASS !! (or ERROR !!)
DTR - RI
:
PASS !! (or ERROR !!)
TD - RD
:
PASS !! (or ERROR !!)
INTERRUPT
:
IRQ XX
"XX" shows the number of interrupt request signal.
If COM1 UART is not accessible, the display shows the following.
Serial I/O COM1 Check
COM1 Channel Disabled
3
Exiting
Pressing the Esc key will exit from this check mode.
2) COM2 Check
1
Check contents
Loop back check is performed to UART at I/O address 2F8H 
2FFH. The check procedures and the exiting procedure are similar
to COM1 check.
3) COM3 Check
1
Check contents
Loop back check is performed to UART at I/O address 3E8H 
3EFH. The check procedures and the exiting procedure are similar
to COM1 check.
4) COM4 Check
1
Check contents
Loop back check is performed to UART at I/O address 2E8H 
2EFH. The check procedures and the exiting procedure are similar
to COM1 check.
5) COM5 Check
1
Check contents
Loop back check is performed to UART at I/O address PSC ad-
dress + (20H 
 27H). The check procedures and the exiting proce-
dure are similar to COM1 check.
6) COM6 Check
1
Check contents
Loop back check is performed to UART at I/O address PSC ad-
dress + (28H 
 2FH).  The check procedures and the exiting pro-
cedure are similar to COM1 check.
3-10. Liquid Crystal Display Diagnostics
This diagnostics is used to check the LCD display of the ER-
A850/A880.
To identify the ER-A850 and the ER-A880, I/O address 3F0H is read
to check the most significant bit. If the most significant bit is "1," it is
judged as the ER-A880. If the most significant bit is "0," it is judged as
the ER-A850.
The test program displays the following patterns in sequence. Press
the space bar to go to the next display. Pressing the space bar at the
final pattern or pressing the Esc key during test will exit from this
check mode to return to the service-man diagnostics menu.
1) Liquid Crystal Display Check
1
Check contents
Test patterns are displayed in the following test procedures. Press
the space bar to go to the next test pattern.
i.
Black-and-white checkered pattern in one-dot interval
ii.
Reversed display of pattern i.
– 18 –