You can assign one satellite to the function of a back-up master. If the master fails during guest
check operation, the assigned terminal will perform the master’s function.
A machine number within the range from 1 to 999999 can be entered.
If zero is entered, there will be no back-up master in the IRC system. 
This job can be done in the INLINE SETTING window of the master. 
The default setting is 0 (no back-up master).
1.
Enter the PGM2 mode.
2.
Select “INLINE SETTING” and press the
key. 
The INLINE SETTING window will open. 
3.
Move the cursor to the “BMA MACHINE NO.” line.
Then enter the machine number of the terminal to
serve as a back-up master and press the
key.
The DECLARATION functions in the PGM2 mode enable the back-up master or the master to
declare to be the master when the master or back-up master breaks down, and inform satellites
of the master’s or back-up master’s recovery. 
For details of these functions, see “Master declaration” and “Recovery declaration” on pages
55–60.
NOTE
ENTER
ENTER
4. Specifying the terminal to serve as a back-up master – master