Read Sharp ER-A750 (serv.man17) Technical Bulletin online
ISSUE OF SPECIAL SERVICE PRESET FOR OVERLAPPED CLERK
SPECIFICATIONS AND TIME IN/BREAK OUT SPECIFICATIONS.
1.Model Name:
ER-A750
2.General:
SSP is issued for the points described below.
2-1. [Phenomenon]
When all of the conditions described below occur at the same time, and a clerk
carries out a finish registration on one of the extension machines, a SIGN ON
occurs on one of the other machines, even though a SIGN OFF has not been
carries out a finish registration on one of the extension machines, a SIGN ON
occurs on one of the other machines, even though a SIGN OFF has not been
carried out.
[Conditions]
[Conditions]
•
In-line system
•
Clerk concentration system
•
Overlapped clerk system
•
Clerk push key or code input system
•
The operation described above is carried out on one of the extension
machines (the problem does not occur if the operation is carried out on the
main machine).
machines (the problem does not occur if the operation is carried out on the
main machine).
Action should be carried out so that a SIGN ON does not occur on any of the
machines when the clerk has not carried out a SIGN OFF when all of the
machines when the clerk has not carried out a SIGN OFF when all of the
conditions listed above have occurred.
2-2. [Phenomenon]
Correct location text is not displayed when the location No. of the location
registration for TIME IN and BREAK OUT is greater than “10".
The problem described above occurs only during display operations, and there
registration for TIME IN and BREAK OUT is greater than “10".
The problem described above occurs only during display operations, and there
have been no problems reported for print-out operations, or for labor cost
calculations. There have also been no problems reported for cases of the location
No. being between ”1" and “9".
calculations. There have also been no problems reported for cases of the location
No. being between ”1" and “9".
Action should be carried out so that the correct location text is displayed.
1/6
ELECTRONIC CASH REGISTER
TECHNICAL BULLETIN
Date :
Model :
Ref :
Colour
Code :
11th January 1999
ERA750
A750-009
White
Sharp Electronics (UK) Ltd, Technical Support Group
Originators Initials_____________ Supervisors Initials_____________ Approval Date____________
3.Description:
The SSP action described below should be carried out for each of the changes which
have been carried out. The input operations of the SSP should be carried out in
accordance with the procedures as described in the SSP Input Procedures document
which is included with this Technical Report.
accordance with the procedures as described in the SSP Input Procedures document
which is included with this Technical Report.
SSP No.
Applicable ROM Version
<1> A change has been carried out in the
overlapped clerk specifications.
∗
The problem does not occur for RAB1B.
SSPERA750-016
RAB1C/RAB1D
<2> A change has been carried out in the TIME
IN/BREAK OUT specifications.
SSPERA750-017
SSPERA750-018
SSPERA750-018
RAB1C/RAB1D/RAB1B
4.Method of
action:
<1> For field.
The SSP described above should be used when the trouble occurs.
<2> For production.
The action described above should be carried out when changes in specifications
are carried out and in cases whereby a change in the ROM is necessary.
are carried out and in cases whereby a change in the ROM is necessary.
2/6
SSP Setting Procedures
<1> Set the machine to SRV MODE, and select DIAGNOSTIC - ROM & SSP
Diagnostic - Standard ROM Check, then confirm the ROM VERSION NUMBER.
(Please refer to the display example provided.)
<2> Carry out the SSP settings in accordance with the SSP setting data provided in
the supplementary document.
<3> Check the print-out receipt with the set DATA to confirm that there are no errors.
<4> In cases whereby an error is detected, set the machine to SRV MODE, select
<4> In cases whereby an error is detected, set the machine to SRV MODE, select
SSP - SSP EDIT, and carry out correction operations to the SSP DATA.
<5> When inserting or pulling out the AC plug to and from the electrical outlets, the
power supply should first be turned OFF, then turned ON once again.
Example Display:
3/6
The underlined portion is the ROM VERSION No.
(In the case of this example, the VERSION No. Is “RAB1C”.)
(In the case of this example, the VERSION No. Is “RAB1C”.)