AH-X10 (serv.man10). Refridgeration cycle - Sharp Air Conditioner Service Manual (repair manual)

ah-x10 (serv.man10) service manual
Model
AH-X10 (serv.man10)
Pages
2 Few pages! See other manuals at the bottom of the first or last page.
Size
21.69 KB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / Refridgeration cycle
File
ah-x10-sm10.pdf
Date

Read Sharp AH-X10 (serv.man10) Service Manual online

30
AH/AY-X08CR
AH/AY-X10CR
AH/AY-X13CR
REFRIGERATION CYCLE
Figure R-1. Refrigeration Cycle for AH-X08CR/10CR/13CR
Figure R-2. Refrigeration Cyclefor AY-X08CR/10CR/13CR
1
2
Capillary tube
3
Outdoor unit
Condenser
Evaporator
Indoor unit
Compressor
Flare coupling
Flare coupling
Silencer
4
3-way
valve
2-way
valve
Silencer
s
1
4
C
2
Capillary 
tube A
Capillary 
tube B
Capillary 
tube C
(2 pieces)
Compressor
3
Strainer
Heating
Cooling
Outdoor unit
Condenser
Evaporator
Indoor unit
Reverse valve
Silencer
Flare coupling
Flare coupling
3-way
valve
2-way
valve
Silencer
Coil
31
AH/AY-X08CR
AH/AY-X10CR
AH/AY-X13CR
Indoor side 
Standard conditions: 
Dry-bulb Temp. (˚C)
Relative Humidity (%)
27
Cooling
47
Outdoor side 
Dry-bulb Temp. (˚C)
Relative Humidity (%)
35
40
AH-X08CR / AH-X10CR / AH-X13CR
Temperature at each part and pressure in 3-way valve
Operation 
mode
Model
Cool
(Max.)
1
2
3
4
3-way valve
pressure
(MPaG)
73˚C
43˚C
10˚C
7˚C
0.9
65
78˚C
43˚C
11˚C
6˚C
0.8
79
87˚C
42˚C
11˚C
9˚C
0.85
97
60˚C
39˚C
13˚C
12˚C
1.1
40 settle
65˚C
40˚C
15˚C
15˚C
1.1
40 settle
Cool
Cool
(Max.)
Cool
Cool
(Max.)
Cool
65˚C
44˚C
15˚C
12˚C
1.1
40 settle
No.
Hz
Dimension of Capillary tube
AH-X08CR
AH-X10CR
AH-X13CR
Model
ø2.7
ø2.7
ø2.7
O.D
ø1.4
ø1.5
ø1.6
500
550
I.D
L
O.D
I.D
L
O.D
I.D
L
500
Capillary tube
AH-X10CR
AH-X08CR
AH-X13CR
Indoor side 
Standard conditions: 
Dry-bulb Temp. (˚C)
Relative Humidity (%)
20
Heating
Outdoor side 
Dry-bulb Temp. (˚C)
Relative Humidity (%)
7
87
27
Cooling
47
35
40
AY-X08CR / AY-X10CR / AY-X13CR
Temperature at each part and pressure in 3-way valve
Operation 
mode
Cool 
(Max.)
Heat 
(Max.)
Cool
Heat
Cool 
(Max.)
Heat 
(Max.)
Cool
Heat
Cool 
(Max.)
Heat 
(Max.)
Cool
Heat
Model
1
2
3
4
3-way valve
pressure
(MPaG)
81˚C
44˚C
9˚C
12˚C
0.90
2.70
1.10
2.20
0.85
2.43
1.10
2.00
0.87
3.05
1.10
2.20
68
85˚C
1˚C
42˚C
38˚C
7˚C
more 
than 70
60˚C
13˚C
12˚C
40 settle
65˚C
2˚C
35˚C
4˚C
50 settle
82˚C
45˚C
11˚C
8˚C
80
78˚C
1˚C
38˚C
6˚C
more 
than 80
65˚C
40˚C
15˚C
12˚C
40 settle
59˚C
2˚C
32˚C
4˚C
50 settle
85˚C
42˚C
12˚C
9˚C
101
91˚C
2˚C
40˚C
6˚C
more 
than 105
65˚C
40˚C
15˚C
15˚C
40 settle
58˚C
3˚C
31˚C
3˚C
50 settle
No.
Hz
Dimension of Capillary tube
AY-X08CR
AY-X10CR
AY-X13CR
Model
ø2.7
ø2.7
ø2.7
O.D
ø1.5
ø1.5
ø1.5
150
150
I.D
L
O.D
I.D
L
O.D
I.D
L
150
Capillary tube C
ø2.7
ø2.7
ø2.7
ø1.4
ø1.6
ø1.6
400
300
600
Capillary tube B
ø2.7
ø2.7
ø2.7
ø1.4
ø1.5
ø1.6
700
550
500
Capillary tube A
AY-X10CR
AY-X08CR
AY-X13CR
Page of 2
Display

Download Sharp AH-X10 (serv.man10) Service Manual (Repair Manual)

Here you can read online and download Sharp AH-X10 (serv.man10) Service Manual in PDF. AH-X10 (serv.man10) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp AH-X10 (serv.man10) Air Conditioner. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.