3.11 Auto Key 
Q.
 How many key depressions are available for an Auto key sequence 
A. 25 
 
3.12 
Q. Can you call an AUTO key menu from within an Auto key sequence 
A. No 
 
3.13 
Q. Can I correct a CCD amount after it has been entered. 
A. Yes this is possible, if you are in the CASH IS screen you simply touch the 
denomination and re enter the correct amount. 
 
3.14 
Q. Can I correct a CCD amount after it has been entered as a Total Amount. 
A. Yes this is possible, you will have go to the CASH IS screen and enter the total 
amount declared via the 1P denomination (E.g. £525.50 enter 52550 for the 1P entry 
and press the VOID key, you now have to re enter the individual lines correctly.
 
 
 
3.15 
Q. Where can I set the text of the CCD denomination amounts from 1 CENT to 1 
PENCE. 
A. PGM2/SETTINGS/MEDIA/CURRENCY MONEY/MONEY1 text change.
 
 
3.16  
Employee Z2 Reset Reports when using “Time In” Compulsory  
Q. My system is set up for compulsory Time in for employee‟s however I also need to 
perform an Employee Z2 Reset report but it is not possible to take this report if the 
Employee is Timed In. Also if the employee is timed out it is not possible to enter the 
X2/Z2 mode, what is the way around this? 
A. Please follow the procedure below: 
1.  Create a new Employee 9999 (This will be the person who tales X2/Z2 
Employee reset report) 
2.  Time in with this Employee and select a Clerk who can perform X2/Z2 
reporting. 
3.  Employee 9999 linked to Clerk is now signed on 
4.  Take the X2/Z2   Employee reset report  but do not include employee 
9999 (i.e range 1 to 999) 
5.  If you do need to reset the employee 9999 take the report again but 
“Time in” as another employee/Clerk and select only to reset 9999. 
 
3.17 Last Void Item Only 
Q. Is it possible to void only the very last entry and prohibit voiding other items by 
the operator? 
A. Yes, please carry out the settings within PGM2/ OPTIONAL/FUNC PROHIBIT/ set 
NO ISSUE VOID to Public and limit the other void settings then change SRV line 922-
A = 6  
 
 
 