UP-800 (serv.man35). UP-800 series FAQ's Updated 21st February 2012 - Sharp ECR FAQ (repair manual). Page 2

Read Sharp UP-800 (serv.man35) FAQ online

2 of 14 
1.6 Receipt Window 
Q.
 How do I change the receipt window display so that the items are displayed on 1 
line. 
A. New service line 986 B=1 
 
1.7 Condiments 
Q. Can I change the colour of the Condiment Lists from being Black text on a Yellow     
background. 
A. NO 
 
1.8 Condiments 
Q. Condiments list are staying down. 
A. Set service line 981 –B =2 
 
1.9 Free Key Programming 
Q.On the UP-800F the Receipt and Journal keys are blank can these be used as 
normal keys. 
A. These buttons are not programmable on the UP-800F 
 
1.9 Free Key Programming 
Q. On the UP-810F there are 2 Receipt keys can one of these keys be used as a 
normal key. 
A. These buttons are not programmable on the UP-810F 
 
1.10 Recall  
Q. What is the RECALL button used for on the Programming Keysheet. 
A. The RECALL button is used for copying the complete details of a PLU‟s to a new 
PLU number. Ie If you want to create an new PLU 35 from an existing PLU 3.  Simply 
highlight PLU 3 within PGM2 / SETTING / ARTICLE / PLU/EAN then press the RECALL 
button then enter the PLU number ie 35. 
 
1.11 Level Shift 
Q. How do I set “Level Shift” to be one shot for the transaction. 
A. Set the following.  
 
PGM2 - Setting - Optional - Function Select1 - LEVEL SHIFT TYPE = AUTO 
PGM2 - Setting - Optional - Function Select1 - LEVEL RETURNTIMING = RECEIPT 
 
1.12 Level Shift 
Q.How do I set “Level Shift” to be staydown. 
A. Set the Following. 
 
     
PGM2 - Setting - Optional - Function Select1 - LEVEL SHIFT TYPE = MANUAL 
PGM2 - Setting - Optional - Function Select1 - LEVEL RETURNTIMING = RECEIPT 
 
1.13 Level Shift 
Q. How do I set a Manager authority against the Level Shift function. 
A. Set LEVEL SHIFT = LIMITED within PGM2 - Setting - Optional - Function Select1
 
 
 
 
 
Page of 14