1.14 Level Shift 
Q.
 How do I set “Level Shift” to be one shot by “ITEM”. 
A. Set the following.  
 
PGM2 - Setting - Optional - Function Select1 - LEVEL SHIFT TYPE = AUTO 
PGM2 - Setting - Optional - Function Select1 - LEVEL RETURNTIMING = ITEM 
 
SRV - Setting - System Preset -980-C =4 
 
1.15 Condiments 
Q. Can I make condiment entries compulsory. 
A. Yes, Within the PGM2 – Setting – Article – PLU/EAN you can set the Main item ie. 
Steak to be Condiment compulsory.  The only way to exit the Condiment is via the 
Cancel key this cannot be disabled. 
 
1.16 PLU’s 
Q. How many PLU menu‟s can I have 
A. Max 50
 
 
1.17 Half Pint 
Q. Can I set the Half pint key to be one shot 
A. Yes Service line 980C=1 
 
1.18 Link PLU 
Q. Is it possible to create a product called Dinner Bed and Breakfast and for a 
portion of this to be assigned to another department. 
A. Yes. Setup a Link PLU table as follows 
 
PLU 1  - Dinner Bed n Breakfast 
 
 
- Price = Zero Price 
 
 
- Menu type is LINK 
 
 
- Combo#/Link# = 01 
 
 
PLU 2  - Accomodation 
Price = £60 
Department 1 
 
 
 
PLU 2  - Food 
Price = £30 
Department 2 
 
PGM 2  - Setting – LINK PLU/EAN TABLE 
Link PLU /EAN TABLE 1 = PLU2 
Link PLU /EAN TABLE 1 = PLU3
 
 
When PLU 1 is sold it will sell at the combined total of the items within the Link Plu 
menu. The department report will show 1 x Dept 1 £60 and 1 x Dept 2 £30 
 
The diner bed and breakfast will also report to its assigned dept, this can be 
assigned to a Hash dept. 
 
One of the differences between Link PLU‟s and Combo menu‟s is that Link plu‟s are 
not itemised on the Bill. 
 